0443005.DR Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse
0443005.DR Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

0443005.DR Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

Share
p0443005.DR: 5 A time-lag (Slo-Blo) Littelfuse 443 Series surface-mount fuse rated for 250 VAC./p
    • Product Details
    • Download

    0443005.DR Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

    For circuits requiring a 5 A protection point, Littelfuse 0443005.DR provides time-lag (Slo-Blo) overcurrent protection in the NANO2 high-voltage SMD (approx. 10.1 × 3.1 mm) platform. The rating is suited to LED lighting systems, provided the startup waveform and ambient rerating are checked against the latest curves. Its 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 250 VAC.

    Best fit: AC/DC adapters using a 5 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 5 A time-lag (Slo-Blo) protection for circuits up to 250 VAC
    • 0.0115 Ω nominal cold resistance for loss and voltage-drop estimation
    • 180.6 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 443 Series
    Part number0443005.DR
    Fuse characteristictime-lag (Slo-Blo)
    Rated current5 A
    Voltage rating250 VAC
    Interrupting rating50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC
    Nominal cold resistance0.0115 Ω
    Nominal melting I²t180.6 A²s
    PackageNANO2 high-voltage SMD (approx. 10.1 × 3.1 mm)
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • AC/DC adapters
    • LED lighting systems
    • telecom power and compact converters

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 5 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 250 VAC; 100 A @ 125 VDC; 500 A @ 60 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the NANO2 high-voltage SMD (approx. 10.1 × 3.1 mm) package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0443005.DR within the 443 Series?
    Its defining electrical point is 5 A with a 250 VAC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 0443005.DR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0443005.DR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the NANO2 high-voltage SMD (approx. 10.1 × 3.1 mm) construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on 24 mm tape-and-reel; quantity/packaging code DR.

    Ordering reference: start with 0443005.DR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd