0452005.NRL Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse
0452005.NRL Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

0452005.NRL Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

Share
Littelfuse 0452005.NRL provides a 5 A fuse option for 125 VAC/VDC board-level circuits.
    • Product Details
    • Download

    0452005.NRL Littelfuse 5 A time-lag (Slo-Blo) NANO2 Fuse

    For circuits requiring a 5 A protection point, Littelfuse 0452005.NRL provides time-lag (Slo-Blo) overcurrent protection in the 2410 / 6125 NANO2 platform. The rating is suited to battery charging circuits, provided the startup waveform and ambient rerating are checked against the latest curves. Its 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 125 VAC/VDC.

    Best fit: battery charging circuits using a 5 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 5 A time-lag (Slo-Blo) protection for circuits up to 125 VAC/VDC
    • 0.0136 Ω nominal cold resistance for loss and voltage-drop estimation
    • 53.72 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 452 Series
    Part number0452005.NRL
    Fuse characteristictime-lag (Slo-Blo)
    Rated current5 A
    Voltage rating125 VAC/VDC
    Interrupting rating50 A @ 125 VAC/VDC; 300 A @ 32 VDC
    Nominal cold resistance0.0136 Ω
    Nominal melting I²t53.72 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • battery charging circuits
    • telecom and networking equipment
    • power supplies with startup surge

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 5 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 125 VAC/VDC; 300 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0452005.NRL within the 452 Series?
    Its defining electrical point is 5 A with a 125 VAC/VDC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 0452005.NRL be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0452005.NRL intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; L suffix identifies the RoHS/halogen-free gold-cap version.

    Ordering reference: start with 0452005.NRL and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd