0452008.NRL 452 Series 8 A PCB Fuse by Littelfuse
0452008.NRL 452 Series 8 A PCB Fuse by Littelfuse

0452008.NRL 452 Series 8 A PCB Fuse by Littelfuse

Share
Compact 2410 / 6125 NANO2 protection at 8 A, Littelfuse 0452008.NRL, time-lag (Slo-Blo).
    • Product Details
    • Download

    0452008.NRL 452 Series 8 A PCB Fuse by Littelfuse

    The 0452008.NRL fuse targets 8 A rails that need time-lag (Slo-Blo) behavior without moving to a cartridge-style footprint. Its 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 72 VAC / 75 VDC. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: battery charging circuits using a 8 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 8 A time-lag (Slo-Blo) protection for circuits up to 72 VAC / 75 VDC
    • 0.0088 Ω nominal cold resistance for loss and voltage-drop estimation
    • 137.34 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 452 Series
    Part number0452008.NRL
    Fuse characteristictime-lag (Slo-Blo)
    Rated current8 A
    Voltage rating72 VAC / 75 VDC
    Interrupting rating50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC
    Nominal cold resistance0.0088 Ω
    Nominal melting I²t137.34 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • battery charging circuits
    • telecom and networking equipment
    • power supplies with startup surge

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 8 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 72 VAC; 50 A @ 60 VDC; 100 A @ 75 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0452008.NRL within the 452 Series?
    Its defining electrical point is 8 A with a 72 VAC / 75 VDC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 0452008.NRL be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0452008.NRL intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; L suffix identifies the RoHS/halogen-free gold-cap version.

    Ordering reference: start with 0452008.NRL and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd