0453015.NR 453 Series 15 A PCB Fuse by Littelfuse
0453015.NR 453 Series 15 A PCB Fuse by Littelfuse

0453015.NR 453 Series 15 A PCB Fuse by Littelfuse

Share
Littelfuse 0453015.NR provides a 15 A fuse option for 65 VAC/VDC board-level circuits.
    • Product Details
    • Download

    0453015.NR 453 Series 15 A PCB Fuse by Littelfuse

    The 0453015.NR fuse targets 15 A rails that need very fast-acting behavior without moving to a cartridge-style footprint. Its 100 A @ 65 VAC; 150 A @ 65 VDC; 400 A @ 32 VDC interrupting specification supports fault-current coordination when the applied voltage remains within 65 VAC/VDC. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies.

    Best fit: notebook and display electronics using a 15 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 15 A very fast-acting protection for circuits up to 65 VAC/VDC
    • 0.0037 Ω nominal cold resistance for loss and voltage-drop estimation
    • 97.82 A²s nominal melting I²t for pulse-withstand and coordination review
    • 100 A @ 65 VAC; 150 A @ 65 VDC; 400 A @ 32 VDC interrupting capability
    • UL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 453 Series
    Part number0453015.NR
    Fuse characteristicvery fast-acting
    Rated current15 A
    Voltage rating65 VAC/VDC
    Interrupting rating100 A @ 65 VAC; 150 A @ 65 VDC; 400 A @ 32 VDC
    Nominal cold resistance0.0037 Ω
    Nominal melting I²t97.82 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • notebook and display electronics
    • networking and telecom equipment
    • secondary-side power rails

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 15 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 100 A @ 65 VAC; 150 A @ 65 VDC; 400 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0453015.NR within the 453 Series?
    Its defining electrical point is 15 A with a 65 VAC/VDC maximum rating and very fast-acting opening behavior.

    Can 0453015.NR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0453015.NR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; the 453 Series does not use an L suffix.

    Ordering reference: start with 0453015.NR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.

    Shenzhen Gaorunxin Technology Co., Ltd