10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR
10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

Share
0453010.NR: 10 A very fast-acting Littelfuse 453 Series surface-mount fuse rated for 125 VAC/VDC.
    • Product Details
    • Download

    10 A very fast-acting Surface-Mount Fuse – Littelfuse 0453010.NR

    Littelfuse 0453010.NR is specified at 10 A and 125 VAC/VDC, giving designers a compact very fast-acting fuse for board-level protection. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies. A nominal cold resistance of 0.0056 Ω helps quantify conduction loss, while the 26.46 A²s nominal melting I²t supports pulse-energy review.

    Best fit: networking and telecom equipment using a 10 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 10 A very fast-acting protection for circuits up to 125 VAC/VDC
    • 0.0056 Ω nominal cold resistance for loss and voltage-drop estimation
    • 26.46 A²s nominal melting I²t for pulse-withstand and coordination review
    • 35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC interrupting capability
    • UL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 453 Series
    Part number0453010.NR
    Fuse characteristicvery fast-acting
    Rated current10 A
    Voltage rating125 VAC/VDC
    Interrupting rating35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC
    Nominal cold resistance0.0056 Ω
    Nominal melting I²t26.46 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL/CSA approvals by rating, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • networking and telecom equipment
    • secondary-side power rails
    • notebook and display electronics

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 10 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 35 A @ 125 VAC; 50 A @ 125 VDC; 400 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0453010.NR within the 453 Series?
    Its defining electrical point is 10 A with a 125 VAC/VDC maximum rating and very fast-acting opening behavior.

    Can 0453010.NR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0453010.NR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; the 453 Series does not use an L suffix.

    Ordering reference: start with 0453010.NR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.