170H0237 Eaton Bussmann 250V 5A Fuse Microswitch
170H0237 Eaton Bussmann 250V 5A Fuse Microswitch

170H0237 Eaton Bussmann 250V 5A Fuse Microswitch

Share
Eaton Bussmann 170H0237 — 250V 5A fuse microswitch.
    • Product Details
    • Download

    170H0237 Eaton Bussmann 250V 5A Fuse Microswitch

    At a Glance
    • 250 V rated voltage, 5 A rated current
    • 2.80 mm x 0.50 mm lug terminations
    • Non-indicating

    The Eaton Bussmann 170H0237 is a high speed fuse with 250 V rated voltage, 5 A rated current. Construction is non-indicating.

    Specifications

    General specifications
    Model Code5A 250V MICROSWITCH T1 00-3
    UPC051712214889
    EAN5027590439077
    Product Length/Depth210 mm
    Product Height55 mm
    Product Width127 mm
    Product Weight30.6 g
    Global Catalog170H0237
    Product specifications
    Amperage Rating5 A
    Accessory/spare part typeMicroswitch
    Fuse indicatorNon-indicating
    Connection2.80 mm x 0.50 mm lug
    Construction sizeOther
    Number of contacts1NO/1NC
    Voltage rating250 V
    TypeFuse Accessory
    ApplicationHigh speed/semiconductor fuses rated up 690V (IEC)/700V (UL)
    Suitable forDIN 43653 Square body fuses size 1* to 3 DIN 43620 size 1 fuses DIN 43620 size 2 fuses Flush end Type T size 00 fuse

    Series Selection Table

    170H0237 series selection table
    Ampere ratings, dimensions and catalog numbers across the High Speed Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Semiconductor fuses are chosen on I²t let-through against the device surge rating, not on continuous current alone.
    • Termination: 2.80 mm x 0.50 mm lug. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann 170H0237?
    250 V / 5 A.
    How does the 170H0237 connect?
    2.80 mm x 0.50 mm lug. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the 170H0237 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products