170H3006 Eaton Bussmann 1400V 1250A Fuse Base
170H3006 Eaton Bussmann 1400V 1250A Fuse Base

170H3006 Eaton Bussmann 1400V 1250A Fuse Base

Share
Eaton Bussmann 170H3006 — 1400V 1250A fuse base. Carries the fuse and provides the circuit connection.
    • Product Details
    • Download

    170H3006 Eaton Bussmann 1400V 1250A Fuse Base

    At a Glance
    • 1400 V rated voltage, 1250 A rated current
    • Screw connection 110 mm Centre distance terminations

    The Eaton Bussmann 170H3006 is a fuse with 1400 V rated voltage, 1250 A rated current.

    Specifications

    General specifications
    Model CodeBASE CA110 1250A 1400V UR 43653
    UPC051712804677
    EAN5027590439169
    Product Length/Depth64 mm
    Product Height77 mm
    Product Width203 mm
    Product Weight1393 g
    Global Catalog170H3006
    Product specifications
    Amperage Rating1250 A
    Number of polesSingle-pole
    Swivelling mechanismNo
    FeaturesHalogen free
    Accessory/spare part typeFixed centre fuse base
    Fitted with:Extra contact
    ConnectionScrew connection 110 mm Centre distance
    Construction sizeOther
    Mounting methodScrew-on
    Quantity1
    Voltage rating1400 V
    Voltage rating – max1400 V
    Connection typeConnector M10
    TypeFuse accessory
    Suitable forDIN 43653 Square body fuses size 1* to 3

    Series Selection Table

    170H3006 series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Screw connection 110 mm Centre distance. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann 170H3006?
    1400 V / 1250 A.
    How does the 170H3006 connect?
    Screw connection 110 mm Centre distance. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the 170H3006 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products