170M3440 Eaton Bussmann 1250V 80A Class aR High Speed Fuse
170M3440 Eaton Bussmann 1250V 80A Class aR High Speed Fuse

170M3440 Eaton Bussmann 1250V 80A Class aR High Speed Fuse

Share
Eaton Bussmann 170M3440 — 1250V 80A Class aR high speed fuse, 100 kAIC interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M3440 Eaton Bussmann 1250V 80A Class aR High Speed Fuse

    At a Glance
    • 1250 V (IEC), 1300 V (UL) rated voltage, 80 A rated current
    • 100 kAIC interrupting rating
    • Class aR time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann 170M3440 is a square body fuse with 1250 V (IEC), 1300 V (UL) rated voltage, 80 A rated current, 100 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    UPC051712256117
    EAN5027590447720
    Product Length/Depth80 mm
    Product Height43 mm
    Product Width60 mm
    Product Weight450.333 g
    Global Catalog170M3440
    Product specifications
    Amperage Rating80 A
    Breaking capacity100 kA
    Fuse indicatorCentre fuse status indicator
    Insulated metal gripping lugs (IMGL)No
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC
    Fuse size1*
    Rated voltage AC1250 V
    Center-to-center distance of connections74 mm
    Current typeAC
    Mounting dimensionM8
    ClassClass aR
    Clearing (I2T)2500 at 1000 V, 3350 at 1250 V
    Watt losses25 W
    Fuse shapeSquare body, flush end contacts
    Pre arc (I2T)420
    ColorNone
    Interrupt rating100 kAIC
    Fitted with:Type K Indicator for micro
    Construction sizeOther
    Mounting methodFlush
    Packaging typeStandard
    Voltage rating1250 V (IEC), 1300 V (UL)
    TypeFuse
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fuse typeFlush end BKN/80 Type K Indicator for Micro
    Fuse system (according to IEC 60269)IEC 60269-4 flush end connections type A

    Series Selection Table

    170M3440 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M3440?
    1250 V (IEC), 1300 V (UL) / 80 A, with a 100 kAIC interrupting rating.
    How much fault current can the 170M3440 interrupt?
    100 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M3440?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M3440 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.