170M3955 Eaton Bussmann 700V 125A Class aR Low Voltage Fuse
170M3955 Eaton Bussmann 700V 125A Class aR Low Voltage Fuse

170M3955 Eaton Bussmann 700V 125A Class aR Low Voltage Fuse

Share
Eaton Bussmann 170M3955 — 700V 125A Class aR low voltage fuse, 150 kAIC interrupting.
    • Product Details
    • Download

    170M3955 Eaton Bussmann 700V 125A Class aR Low Voltage Fuse

    At a Glance
    • 700 V (UL), 600 V (IEC) rated voltage, 125 A rated current
    • 150 kAIC interrupting rating
    • Class aR time-current characteristic
    • Flush-end contact terminations

    The Eaton Bussmann 170M3955 is a low voltage fuse with 700 V (UL), 600 V (IEC) rated voltage, 125 A rated current, 150 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is non indicating.

    Specifications

    General specifications
    UPC051712678803
    Product Length/Depth61 mm
    Product Height72.5 mm
    Product Width43 mm
    Product Weight956 g
    Product specifications
    Amperage Rating125 A
    Fuse indicatorNon Indicating
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC
    Fuse size1*
    ClassClass aR
    Clearing (I2T)8600 at 1000 V
    Watt losses40 W
    Fuse shapeSquare Body size 1* to 3, flush-end contact
    Pre arc (I2T)1450
    Interrupt rating150 kAIC
    Fitted with:Type K Indicator for micro
    ConnectionFlush-end contact
    Mounting methodFlush
    Packaging typeStandard
    Voltage rating700 V (UL), 600 V (IEC)
    TypeSquare body flush end contact -BKN/- type K indicator for micro
    ApplicationDC common bus DC drives power converters/rectifiers reduced voltage starters
    Fuse typeFlush end BKN/Type K Indicator for Micro

    Series Selection Table

    170M3955 series selection table
    Ampere ratings, dimensions and catalog numbers across the Low Voltage Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Flush-end contact. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M3955?
    700 V (UL), 600 V (IEC) / 125 A, with a 150 kAIC interrupting rating.
    How much fault current can the 170M3955 interrupt?
    150 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M3955?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the 170M3955 connect?
    Flush-end contact. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the 170M3955 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.