170M4493 Eaton Bussmann 1250V 400A Class aR High Speed Fuse
170M4493 Eaton Bussmann 1250V 400A Class aR High Speed Fuse

170M4493 Eaton Bussmann 1250V 400A Class aR High Speed Fuse

Share
Eaton Bussmann 170M4493 — 1250V 400A Class aR high speed fuse. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M4493 Eaton Bussmann 1250V 400A Class aR High Speed Fuse

    At a Glance
    • 1250 V rated voltage, 400 A rated current
    • Class aR time-current characteristic
    • Flush end GKN/75 Type K indicator for micro

    The Eaton Bussmann 170M4493 is a square body fuse with 1250 V rated voltage, 400 A rated current, carrying a Class aR time-current characteristic.

    Specifications

    General specifications
    UPC051712259057
    EAN5704057026055
    Product Length/Depth51.1 mm
    Product Height66.5 mm
    Product Width51.2 mm
    Product Weight0.001 g
    Global Catalog170M4493
    Product specifications
    Amperage Rating400 A
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC/DC
    Fuse size1
    ClassClass aR
    Clearing (I2T)175000 at 1000 V, 235000 at 1250 V
    Watt losses75 W
    Pre arc (I2T)29500
    Fitted with:Type K Indicator for micro
    Mounting methodFlush
    Packaging typeStandard
    Quantity1
    Voltage rating1250 V
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fuse typeFlush end GKN/75 Type K indicator for micro

    Series Selection Table

    170M4493 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M4493?
    1250 V / 400 A.
    What does Class aR mean for the 170M4493?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M4493 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message