Eaton Bussmann 170M4959 — 1000V 550A Class aR square body fuse, 125 kAIC interrupting. Protects DC links and battery strings in high-current systems.
    • Product Details
    • Download

    170M4959 Eaton Bussmann 1000V 550A Class aR Square Body Fuse

    At a Glance
    • 1000 V (IEC) rated voltage, 550 A rated current
    • 125 kAIC interrupting rating
    • Class aR time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann 170M4959 is a square body fuse with 1000 V (IEC) rated voltage, 550 A rated current, 125 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    EAN5027590455121
    UPC051712679510
    Product Length/Depth73 mm
    Product Height52 mm
    Product Width170 mm
    Product Weight576 g
    Electrical data
    Amperage Rating550 A
    ClassClass aR
    Interrupt rating125 kAIC
    Voltage rating1000 V (IEC)
    Watt losses90 W
    Product specifications
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fitted with:Type K Indicator for micro
    Fuse indicatorCentre fuse status indicator
    Fuse size1
    Fuse typeFlush end BKN/Type K Indicator for Micro

    Series Selection Table

    170M4959 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M4959?
    1000 V (IEC) / 550 A, with a 125 kAIC interrupting rating.
    How much fault current can the 170M4959 interrupt?
    125 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M4959?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M4959 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.