    At a Glance
    • 1250 V (IEC), 1300 V (UL) rated voltage, 800 A rated current
    • 100 kA interrupting rating
    • Class aR time-current characteristic

    The Eaton Bussmann 170M5498 is a square body fuse with 1250 V (IEC), 1300 V (UL) rated voltage, 800 A rated current, 100 kA interrupting capacity, carrying a Class aR time-current characteristic.

    Specifications

    General specifications
    UPC051712261456
    EAN5027590457491
    Model CodeFUSE 800A 1250V 2BKN/90 AR CU
    Product Length/Depth168 mm
    Product Height80 mm
    Product Width124 mm
    Product Weight818 g
    Electrical data
    Amperage Rating800 A
    Voltage rating1250 V (IEC), 1300 V (UL)
    Voltage typeAC
    Clearing (I2T)1200000 at 1000 V, 1550000 at 1250 V
    Pre arc (I2T)245000
    Watt losses120 W
    Breaking capacity100 kA
    ClassClass aR
    Product specification
    Fuse size2
    Fitted with:Type K Indicator for micro

    Series Selection Table

    170M5498 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M5498?
    1250 V (IEC), 1300 V (UL) / 800 A, with a 100 kA interrupting rating.
    How much fault current can the 170M5498 interrupt?
    100 kA. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M5498?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M5498 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.