170M5648 Eaton Bussmann 1300V 800A Class aR High Speed Fuse
170M5648 Eaton Bussmann 1300V 800A Class aR High Speed Fuse

170M5648 Eaton Bussmann 1300V 800A Class aR High Speed Fuse

Share
Eaton Bussmann 170M5648 — 1300V 800A Class aR high speed fuse, 100 kAIC interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M5648 Eaton Bussmann 1300V 800A Class aR High Speed Fuse

    At a Glance
    • 1300 V (UL), 1250 V (IEC) rated voltage, 800 A rated current
    • 100 kAIC interrupting rating
    • Class aR time-current characteristic
    • Non Indicating

    The Eaton Bussmann 170M5648 is a square body fuse with 1300 V (UL), 1250 V (IEC) rated voltage, 800 A rated current, 100 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is non indicating.

    Specifications

    General specifications
    UPC051712261951
    Product Length/Depth3.03 in
    Product Height3.58 in
    Product Width2.4 in
    Product Weight828.75 lb
    Electrical data
    Amperage Rating800 A
    ClassClass aR
    Clearing (I2T)1200000 at 1000 V 1550000 at 1250 V
    Interrupt rating100 kAIC
    Pre arc (I2T)245000
    Voltage rating1300 V (UL), 1250 V (IEC)
    Watt losses120 W
    Product specifications
    ApplicationDC common bus DC drives power converters/rectifiers
    Fuse indicatorNon Indicating
    Fuse size2
    Fuse typeGKN/90 Type K indicator for micro

    Series Selection Table

    170M5648 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M5648?
    1300 V (UL), 1250 V (IEC) / 800 A, with a 100 kAIC interrupting rating.
    How much fault current can the 170M5648 interrupt?
    100 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M5648?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M5648 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.