170M6543 Eaton Bussmann 1250V 550A Class aR High Speed Fuse
170M6543 Eaton Bussmann 1250V 550A Class aR High Speed Fuse

170M6543 Eaton Bussmann 1250V 550A Class aR High Speed Fuse

Share
Eaton Bussmann 170M6543 — 1250V 550A Class aR high speed fuse, 100 kAIC interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M6543 Eaton Bussmann 1250V 550A Class aR High Speed Fuse

    At a Glance
    • 1250 V (IEC), 1300 V (UL) rated voltage, 550 A rated current
    • 100 kAIC interrupting rating
    • Class aR time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann 170M6543 is a square body fuse with 1250 V (IEC), 1300 V (UL) rated voltage, 550 A rated current, 100 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    EAN5996516019733
    UPC051712264471
    Product Length/Depth168 mm
    Product Height76 mm
    Product Width95 mm
    Product Weight1.289 g
    Electrical data
    Amperage Rating550 A
    ClassClass aR
    Clearing (I2T)325000 at 1000 V, 435000 at 1250 V
    Interrupt rating100 kAIC
    Pre arc (I2T)55000
    Voltage rating1250 V (IEC), 1300 V (UL)
    Watt losses110 W
    Product specifications
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fitted with:Type K Indicator for micro
    Fuse indicatorCentre fuse status indicator
    Fuse size3
    Fuse typeFlush end BKN/80 Type K Indicator for Micro

    Series Selection Table

    170M6543 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M6543?
    1250 V (IEC), 1300 V (UL) / 550 A, with a 100 kAIC interrupting rating.
    How much fault current can the 170M6543 interrupt?
    100 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M6543?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M6543 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message