170M8509 Eaton Bussmann 1000V 900A Class aR High Speed Fuse
170M8509 Eaton Bussmann 1000V 900A Class aR High Speed Fuse

170M8509 Eaton Bussmann 1000V 900A Class aR High Speed Fuse

Share
Eaton Bussmann 170M8509 — 1000V 900A Class aR high speed fuse, 125 kAIC interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M8509 Eaton Bussmann 1000V 900A Class aR High Speed Fuse

    At a Glance
    • 1000 V (IEC) rated voltage, 900 A rated current
    • 125 kAIC interrupting rating
    • Class aR time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann 170M8509 is a square body fuse with 1000 V (IEC) rated voltage, 900 A rated current, 125 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    EAN5027590465175
    UPC051712603843
    Product Length/Depth90 mm
    Product Height74 mm
    Product Width160 mm
    Product Weight915 g
    Electrical data
    Amperage Rating900 A
    ClassClass aR
    Interrupt rating125 kAIC
    Voltage rating1000 V (IEC)
    Watt losses145 W
    Product specifications
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fuse indicatorCentre fuse status indicator
    Fuse size3
    Fuse typeFlush end GKN/Type K indicator for micro

    Series Selection Table

    170M8509 series selection table
    Ampere ratings, dimensions and catalog numbers across the Square Body Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M8509?
    1000 V (IEC) / 900 A, with a 125 kAIC interrupting rating.
    How much fault current can the 170M8509 interrupt?
    125 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M8509?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M8509 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message