    Littelfuse 0454.375NR is specified at 375 mA and 125 VAC/VDC, giving designers a compact time-lag (Slo-Blo) fuse for board-level protection. The -55 °C to +125 °C operating range broadens its use across compact power-conversion and control assemblies. A nominal cold resistance of 1.2000 Ω helps quantify conduction loss, while the 0.101 A²s nominal melting I²t supports pulse-energy review.

    Best fit: storage and server equipment using a 375 mA protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 375 mA time-lag (Slo-Blo) protection for circuits up to 125 VAC/VDC
    • 1.2000 Ω nominal cold resistance for loss and voltage-drop estimation
    • 0.101 A²s nominal melting I²t for pulse-withstand and coordination review
    • 50 A @ 125 VAC/VDC; 300 A @ 32 VDC interrupting capability
    • UL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 454 Series
    Part number0454.375NR
    Fuse characteristictime-lag (Slo-Blo)
    Rated current375 mA
    Voltage rating125 VAC/VDC
    Interrupting rating50 A @ 125 VAC/VDC; 300 A @ 32 VDC
    Nominal cold resistance1.2000 Ω
    Nominal melting I²t0.101 A²s
    Package2410 / 6125 NANO2
    Operating temperature-55 °C to +125 °C
    Agency / environmentalUL Recognized, CSA Certified, IEC/EN 60127 compliant, RoHS compliant and halogen-free

    Best-Fit Applications

    • storage and server equipment
    • white goods and industrial electronics
    • power supplies with startup surge

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 375 mA rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 50 A @ 125 VAC/VDC; 300 A @ 32 VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 2410 / 6125 NANO2 package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 0454.375NR within the 454 Series?
    Its defining electrical point is 375 mA with a 125 VAC/VDC maximum rating and time-lag (Slo-Blo) opening behavior.

    Can 0454.375NR be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 0454.375NR intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 2410 / 6125 NANO2 construction.

    Ordering and Packaging

    Packaging: 1,000-piece MR or 5,000-piece NR tape-and-reel; 454 is supplied as RoHS/halogen-free without an L suffix.

    Ordering reference: start with 0454.375NR and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.