The Eaton Bussmann 400LMMT is a high speed fuse rated 240VAC at 400A and with a 200kA (a.c.), 40kA (d.c.) interrupting rating. It is used for DC links and semiconductor stacks that need sub-millisecond clearing. 400A 240VAC/150 VDC, 200kA, Class aR, BS88 High Speed Fuse, DC Fuse.
| Catalog Number | 400LMMT |
| Series | Bussmann BS88 LMMT |
| Product Type | BS88 high speed fuse link (bolted tags) |
| Rated Voltage AC | 240V a.c. (IEC) / 250V a.c. (UL) |
| Rated Voltage DC | 150V d.c. |
| Rated Current | 400A |
| Breaking Capacity | 200kA (a.c.), 40kA (d.c.) |
| Pre-arcing I²t | 6000 A²s |
| Clearing I²t at 120 V / 240 V a.c. | 35,000 / 80,000 A²s |
| Power Loss at Rated Current | 60 W |
| Standards | BS88 part 4, IEC 60269-4, UL Recognized |
| Application | Protection of power semiconductors, rectifiers, DC drives and power converters |
| Dimensions | Full size drawing ↓ |
| Model | Current | Voltage | Class |
|---|---|---|---|
| 400LMMT | 400A | 240VAC | — |
| 400LMMT | 400A | 240VAC | — |
| 400LMT | 400A | 240VAC | — |
3 models in the 400L family, sorted by rated current.
Protection of power semiconductors, rectifiers, DC drives and power converters.
DC links and semiconductor stacks that need sub-millisecond clearing.
Match the fuse I²t to the device it protects; a larger fuse protects the cable but not the semiconductor.
For DC circuits confirm the time constant, since clearing time depends on the circuit L/R.
What is the 400LMMT rated for?
It is rated 240VAC at 400A. The interrupting rating is 200kA (a.c.), 40kA (d.c.).
What class is this fuse?
The class is not stated on the manufacturer page; confirm on the datasheet before ordering.
Can I replace it with a different class?
No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.
What does the interrupting rating mean?
It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.
How do I verify the part number?
Order by the full catalog number 400LMMT; suffixes change the terminal, voltage or package.
Where can I find the datasheet?
The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.