46214000000 Littelfuse 4 A time-lag NANO2 Fuse
46214000000 Littelfuse 4 A time-lag NANO2 Fuse

46214000000 Littelfuse 4 A time-lag NANO2 Fuse

Share
Littelfuse 46214000000 provides a 4 A fuse option for 250 VAC/VDC IEC; 350 VAC/VDC UL board-level circuits.
    • Product Details
    • Download

    46214000000 Littelfuse 4 A time-lag NANO2 Fuse

    For circuits requiring a 4 A protection point, Littelfuse 46214000000 provides time-lag overcurrent protection in the 10.5 × 4.5 mm NANO2 UMF platform. The rating is suited to AC/DC adapter primary protection, provided the startup waveform and ambient rerating are checked against the latest curves. Its 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting specification supports fault-current coordination when the applied voltage remains within 250 VAC/VDC IEC; 350 VAC/VDC UL.

    Best fit: AC/DC adapter primary protection using a 4 A protection point. Key check: validate normal current, inrush waveform, available fault current and ambient-temperature rerating before approval.

    Why Choose This Rating

    • 4 A time-lag protection for circuits up to 250 VAC/VDC IEC; 350 VAC/VDC UL
    • 0.0158 Ω nominal cold resistance for loss and voltage-drop estimation
    • 21.0 A²s nominal melting I²t for pulse-withstand and coordination review
    • 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC interrupting capability
    • UL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Core Specifications

    ParameterValue
    Manufacturer / SeriesLittelfuse / 462 Series
    Part number46214000000
    Fuse characteristictime-lag
    Rated current4 A
    Voltage rating250 VAC/VDC IEC; 350 VAC/VDC UL
    Interrupting rating100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC
    Nominal cold resistance0.0158 Ω
    Nominal melting I²t21.0 A²s
    Package10.5 × 4.5 mm NANO2 UMF
    Operating temperature-40 °C to +85 °C
    Agency / environmentalUL Recognized, IEC 60127-4 UMF approvals, RoHS compliant, halogen-free and lead-free

    Best-Fit Applications

    • AC/DC adapter primary protection
    • high-voltage DC distribution
    • lighting ballasts

    Selection Guidance

    For continuous service, begin the design review at no more than 75% of the 4 A rating, then apply the temperature-rerating curve and confirm the time-current response against startup and fault waveforms. The percentage is a design starting point, not a substitute for application testing.

    Check that the prospective fault current stays within 100 A @ 350 VAC/VDC; 150 A @ 250 VAC/VDC at the applied voltage. Use the manufacturer-recommended land pattern for the 10.5 × 4.5 mm NANO2 UMF package and validate thermal behavior on the intended copper layout.

    Frequently Asked Questions

    What distinguishes 46214000000 within the 462 Series?
    Its defining electrical point is 4 A with a 250 VAC/VDC IEC; 350 VAC/VDC UL maximum rating and time-lag opening behavior.

    Can 46214000000 be chosen by current rating alone?
    No. Normal load, ambient temperature, pulse energy, time-current behavior and available short-circuit current all affect suitability.

    Is 46214000000 intended for automated PCB assembly?
    Yes. It is a surface-mount fuse; follow the latest soldering profile, pad layout and orientation guidance for the 10.5 × 4.5 mm NANO2 UMF construction.

    Ordering and Packaging

    Packaging: 1,500 pieces on 16 mm tape-and-reel; packaging code 0.

    Ordering reference: start with 46214000000 and confirm the exact reel, termination and compliance suffix against current stock before purchase.

    Design note: Resistance and I²t values are nominal unless identified as ratings. Verify the latest Littelfuse data sheet and curves before final release.