80LET Eaton Bussmann 240V 80A Semiconductor Fuse
80LET Eaton Bussmann 240V 80A Semiconductor Fuse

80LET Eaton Bussmann 240V 80A Semiconductor Fuse

Share
Eaton Bussmann 80LET, 240V, 80A semiconductor fuse, 200kA (a.c.), 50kA (d.c.) interrupting.
    • Product Details
    • Download
    At a Glance
    • Rated current 80A
    • Rated voltage 240V
    • Interrupting rating 200kA (a.c.), 50kA (d.c.)

    The Eaton Bussmann 80LET is a semiconductor fuse rated 240V at 80A and with a 200kA (a.c.), 50kA (d.c.) interrupting rating. It is used for rectifiers, drives and inverters where the fuse must protect the diode or thyristor. LET 80 Amp, 240V, Semiconductor, Bussmann 80LET, LET 80A | aka: Cooper Bussmann 80LET, Eaton 80LET.

    Key Specifications

    Catalog Number80LET
    SeriesBussmann BS88 LET
    Product TypeBS88 high speed fuse link (bolted tags)
    Rated Voltage AC240V a.c. (IEC) / 250V a.c. (UL)
    Rated Voltage DC150V d.c.
    Rated Current80A
    Breaking Capacity200kA (a.c.), 50kA (d.c.)
    Pre-arcing I²t300 A²s
    Clearing I²t at 240 V a.c.3800 A²s
    Power Loss at Rated Current10 W
    StandardsBS88 part 4, IEC 60269-4, UL Recognized
    ApplicationProtection of power semiconductors, rectifiers, DC drives and power converters
    DimensionsFull size drawing ↓

    Applications

    Protection of power semiconductors, rectifiers, DC drives and power converters.

    Rectifiers, drives and inverters where the fuse must protect the diode or thyristor.

    Selection Notes

    Size the fuse on the semiconductor's I²t, not on the load current — the fuse must clear before the die is damaged.

    Check the DC voltage derating: a fuse rated for AC duty often carries a lower DC rating.

    Common Questions

    What is the 80LET rated for?

    It is rated 240V at 80A. The interrupting rating is 200kA (a.c.), 50kA (d.c.).

    What class is this fuse?

    The class is not stated on the manufacturer page; confirm on the datasheet before ordering.

    Can I replace it with a different class?

    No. Fuse classes differ in dimensions and rejection features, so a different class will not fit the holder and may not provide the same protection.

    What does the interrupting rating mean?

    It is the maximum fault current the fuse can safely interrupt. It must be at least as high as the available fault current at the installation point.

    How do I verify the part number?

    Order by the full catalog number 80LET; suffixes change the terminal, voltage or package.

    Where can I find the datasheet?

    The manufacturer datasheet is the authority for derating curves, I²t and agency approvals for this catalog number.

    Source: manufacturer catalog page for 80LET. Verify ratings against the current datasheet before ordering.