CRM25TE09FA CR Micro 250V 9A IPM SOP-11
CRM25TE09FA CR Micro 250V 9A IPM SOP-11

CRM25TE09FA CR Micro 250V 9A IPM SOP-11

Share
pCRM25TE09FA CR Micro 250V 9A IPM SOP-11 — half-bridge./p
    • Product Details
    • Download
    At a Glance
    • 250 V / 9 A output rating, SOP-11
    • Half-bridge topology

    The CR Micro CRM25TE09FA is a 250 V 9 A intelligent power module in a SOP-11 package, wired as a half-bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Pumps.

    Key Specifications

    Blocking Voltage (VDSS / VCES)250 V
    Output Current (ID / IC)9 A
    Power StageMOSFET
    Circuit Configurationhalf-bridge
    Rds(on) typ.0.55 mΩ
    Rds(on) max.0.8 mΩ
    Built-in Protectionvot
    Typical ApplicationFans and Pumps
    PackageSOP-11

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    CRM25TD07R1250V7Ahalf-bridgeQFN 7x7
    CRM25TE09FA250V9Ahalf-bridgeSOP-11

    2 part numbers share the same 250 / half-bridge rating — sorted by current.

    Applications

    Fans and Pumps — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the CRM25TE09FA implement?

    It is a half-bridge module rated 250 V / 9 A.

    What protection is built into the CRM25TE09FA?

    The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the CRM25TE09FA intended for?

    Fans and Pumps — a match for the module's power rating and package thermal path.

    What package does the CRM25TE09FA come in?

    SOP-11. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 2 part numbers in this rating group?

    All 2 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.