CRM60TD03R1 CR Micro 600V 3A IPM QFN 7x7
CRM60TD03R1 CR Micro 600V 3A IPM QFN 7x7

CRM60TD03R1 CR Micro 600V 3A IPM QFN 7x7

Share
pCRM60TD03R1 CR Micro 600V 3A IPM QFN 7x7 — half-bridge./p
    • Product Details
    • Download
    At a Glance
    • 600 V / 3 A output rating, QFN 7x7
    • Half-bridge topology

    The CR Micro CRM60TD03R1 is a 600 V 3 A intelligent power module in a QFN 7x7 package, wired as a half-bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.

    Key Specifications

    Blocking Voltage (VDSS / VCES)600 V
    Output Current (ID / IC)3 A
    Power StageMOSFET
    Circuit Configurationhalf-bridge
    Rds(on) typ.2.4 mΩ
    Rds(on) max.3 mΩ
    Built-in Protectionvot
    Typical ApplicationFans and Hair dryer
    PackageQFN 7x7

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    CRM60TD01R1600V1Ahalf-bridgeQFN 7x7
    CS5762ASCO600V2Ahalf-bridgeWSOP13
    CRM60TD03R1600V3Ahalf-bridgeQFN 7x7
    CS5763AHMO600V3Ahalf-bridgeESOP12
    CRM60TE04HA600V4Ahalf-bridgeSOP-11
    CS5764AHMO600V4Ahalf-bridgeESOP12
    CS5764ASCO600V4Ahalf-bridgeWSOP13
    CS5764SCO600V4Ahalf-bridgeWSOP13
    CS5764SDQ600V4Ahalf-bridgeQFN18
    CRM60TD05R1600V5Ahalf-bridgeQFN 7x7
    CS5765AHGO600V5Ahalf-bridge1.5VESOP12
    CS5765ASGO600V5Ahalf-bridge1.5VWSOP13
    CS5765SGO600V5Ahalf-bridge1.5VWSOP13
    CS5765SGQ600V5Ahalf-bridge1.5VQFN18
    CRM60TE06HA600V6Ahalf-bridgeSOP-11
    CS5766AHMO600V6Ahalf-bridgeESOP12
    CS5766ASCO600V6Ahalf-bridgeWSOP13

    17 part numbers share the same 600 / half-bridge rating — sorted by current.

    Applications

    Fans and Hair dryer — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the CRM60TD03R1 implement?

    It is a half-bridge module rated 600 V / 3 A.

    What protection is built into the CRM60TD03R1?

    The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the CRM60TD03R1 intended for?

    Fans and Hair dryer — a match for the module's power rating and package thermal path.

    What package does the CRM60TD03R1 come in?

    QFN 7x7. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 17 part numbers in this rating group?

    All 17 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.