The CR Micro CRMT5002E1 is a 500 V 4 A intelligent power module in a SOP-23A package, wired as a 3-phase full bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.
| Blocking Voltage (VDSS / VCES) | 500 V |
| Output Current (ID / IC) | 4 A |
| Power Stage | MOSFET |
| Circuit Configuration | 3-phase full bridge |
| Rds(on) typ. | 1.7 mΩ |
| Rds(on) max. | 2.1 mΩ |
| Built-in Protection | vot |
| Typical Application | Fans and Hair dryer |
| Package | SOP-23A |
| Part Number | VDSS/VCES | ID/IC | Configuration | VCE(sat) typ | Package |
|---|---|---|---|---|---|
| CRM50TA02E1 | 500V | 2A | 3-phase full bridge | DIP-23E | |
| CRMT5000E1 | 500V | 2A | 3-phase full bridge | SOP-23A | |
| CS5752ATO | 500V | 2A | 3-phase full bridge | SOP-23H | |
| CS5752ATP | 500V | 2A | 3-phase full bridge | DIP-23H | |
| CS5752NTO | 500V | 2A | 3-phase full bridge | SOP-23H | |
| CRM50T03FA | 500V | 3A | 3-phase full bridge | SOP-23A | |
| CRM50TA04E1 | 500V | 4A | 3-phase full bridge | DIP-23E | |
| CRMT5002E1 | 500V | 4A | 3-phase full bridge | SOP-23A | |
| CS5754NTO | 500V | 4A | 3-phase full bridge | SOP-23H | |
| CS5755MTO | 500V | 5A | 3-phase full bridge | SOP-23H | |
| CS5755MTP | 500V | 5A | 3-phase full bridge | DIP-23H | |
| CS5755NTO | 500V | 5A | 3-phase full bridge | SOP-23H | |
| CRM50TA06E1 | 500V | 6A | 3-phase full bridge | DIP-23E | |
| CRMT5004E1 | 500V | 6A | 3-phase full bridge | SOP-23A |
14 part numbers share the same 500 / 3-phase full bridge rating — sorted by current.
Fans and Hair dryer — the module's rating and package are sized for this class of load.
What topology does the CRMT5002E1 implement?
It is a 3-phase full bridge module rated 500 V / 4 A.
What protection is built into the CRMT5002E1?
The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.
What applications is the CRMT5002E1 intended for?
Fans and Hair dryer — a match for the module's power rating and package thermal path.
What package does the CRMT5002E1 come in?
SOP-23A. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.
How do I choose between the 14 part numbers in this rating group?
All 14 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd