CRMT5004E1 CR Micro 500V 6A IPM SOP-23A
CRMT5004E1 CR Micro 500V 6A IPM SOP-23A

CRMT5004E1 CR Micro 500V 6A IPM SOP-23A

Share
pCRMT5004E1 CR Micro 500V 6A IPM SOP-23A — 3-phase full bridge./p
    • Product Details
    • Download
    At a Glance
    • 500 V / 6 A output rating, SOP-23A
    • 3-phase full bridge topology

    The CR Micro CRMT5004E1 is a 500 V 6 A intelligent power module in a SOP-23A package, wired as a 3-phase full bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.

    Key Specifications

    Blocking Voltage (VDSS / VCES)500 V
    Output Current (ID / IC)6 A
    Power StageMOSFET
    Circuit Configuration3-phase full bridge
    Rds(on) typ.1.2 mΩ
    Rds(on) max.1.5 mΩ
    Built-in Protectionvot
    Typical ApplicationFans and Hair dryer
    PackageSOP-23A

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    CRM50TA02E1500V2A3-phase full bridgeDIP-23E
    CRMT5000E1500V2A3-phase full bridgeSOP-23A
    CS5752ATO500V2A3-phase full bridgeSOP-23H
    CS5752ATP500V2A3-phase full bridgeDIP-23H
    CS5752NTO500V2A3-phase full bridgeSOP-23H
    CRM50T03FA500V3A3-phase full bridgeSOP-23A
    CRM50TA04E1500V4A3-phase full bridgeDIP-23E
    CRMT5002E1500V4A3-phase full bridgeSOP-23A
    CS5754NTO500V4A3-phase full bridgeSOP-23H
    CS5755MTO500V5A3-phase full bridgeSOP-23H
    CS5755MTP500V5A3-phase full bridgeDIP-23H
    CS5755NTO500V5A3-phase full bridgeSOP-23H
    CRM50TA06E1500V6A3-phase full bridgeDIP-23E
    CRMT5004E1500V6A3-phase full bridgeSOP-23A

    14 part numbers share the same 500 / 3-phase full bridge rating — sorted by current.

    Applications

    Fans and Hair dryer — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the CRMT5004E1 implement?

    It is a 3-phase full bridge module rated 500 V / 6 A.

    What protection is built into the CRMT5004E1?

    The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the CRMT5004E1 intended for?

    Fans and Hair dryer — a match for the module's power rating and package thermal path.

    What package does the CRMT5004E1 come in?

    SOP-23A. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 14 part numbers in this rating group?

    All 14 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message