CRMT6002E1 CR Micro 600V 3A IPM SOP-23A
CRMT6002E1 CR Micro 600V 3A IPM SOP-23A

CRMT6002E1 CR Micro 600V 3A IPM SOP-23A

Share
pCRMT6002E1 CR Micro 600V 3A IPM SOP-23A — 3-phase full bridge./p
    • Product Details
    • Download
    At a Glance
    • 600 V / 3 A output rating, SOP-23A
    • 3-phase full bridge topology

    The CR Micro CRMT6002E1 is a 600 V 3 A intelligent power module in a SOP-23A package, wired as a 3-phase full bridge using MOSFET power stages. Protection on board covers under-voltage lockout. Designed for Fans and Hair dryer.

    Key Specifications

    Blocking Voltage (VDSS / VCES)600 V
    Output Current (ID / IC)3 A
    Power StageMOSFET
    Circuit Configuration3-phase full bridge
    Rds(on) typ.2.4 mΩ
    Rds(on) max.3 mΩ
    Built-in Protectionvot
    Typical ApplicationFans and Hair dryer
    PackageSOP-23A

    Same-Rating Selection Table

    Part NumberVDSS/VCESID/ICConfigurationVCE(sat) typPackage
    CRM60TA01E1600V1A3-phase full bridgeDIP-23E
    CRMT6000E1600V1A3-phase full bridgeSOP-23A
    CS5762MTO600V2A3-phase full bridgeSOP-23H
    CS5762NTP600V2A3-phase full bridgeDIP-23H
    CRM60TA03E1600V3A3-phase full bridgeDIP-23E
    CRMT6002E1600V3A3-phase full bridgeSOP-23A
    DPM03C60LM600V3A3-phase full bridgeSDIP26
    DPM03T60BM600V3A3-phase full bridgeDIP24-1
    DPM03T60RMP600V3A3-phase full bridge2.5VSDIP24
    CS5764MTO600V4A3-phase full bridgeSOP-23H
    CS5764MTP600V4A3-phase full bridgeDIP-23H
    CS5764NTO600V4A3-phase full bridgeSOP-23H
    CS5764NTP600V4A3-phase full bridgeDIP-23H
    DPM04T60AM600V4A3-phase full bridgeDIP24
    DPM04T60BM600V4A3-phase full bridgeDIP24-1
    CRM60TA05E1600V5A3-phase full bridgeDIP-23E
    CRMT6004E1600V5A3-phase full bridgeSOP-23A
    CS5765NGO600V5A3-phase full bridge1.5VSOP-23H
    CS5765NGP600V5A3-phase full bridge1.5VDIP-23H
    CRM60G06E1600V6A3-phase full bridge1.7VSOP-23A
    CRM60GA06E1600V6A3-phase full bridge1.7VDIP-23E
    CRM60GK06E4/CRM60GK06E4-S59600V6A3-phase full bridge1.9VDIP-25A
    CS5766NTO600V6A3-phase full bridgeSOP-23H
    CS5766NTP600V6A3-phase full bridgeDIP-23H
    DPM06C60LG600V6A3-phase full bridge1.8VSDIP26
    DPM06T60CG1600V6A3-phase full bridge1.8VDIP25
    DPM06T60CG3600V6A3-phase full bridge1.8VDIP25
    DPM06T60CG4600V6A3-phase full bridge1.8VDIP25
    DPM06T60CGS3600V6A3-phase full bridge1.8VDIP25-2
    DPM06T60CGS4600V6A3-phase full bridge1.8VDIP25-2
    DPM06T60RGO2600V6A3-phase full bridge1.9VSSOP24
    DPM06T60RGP2600V6A3-phase full bridge1.9VSDIP24
    DPM06T60UGO1600V6A3-phase full bridge1.7VSSOP38
    CRM60G10FA600V10A3-phase full bridge1.4VSOP-23A
    CRM60GH10E4600V10A3-phase full bridge1.7VDIP-24B
    CRM60GK10E4/CRM60GK10E4-S59600V10A3-phase full bridge1.9VDIP-25A
    DPM10C60DG1600V10A3-phase full bridge2.0VDIP-24H
    DPM10T60CG2600V10A3-phase full bridge1.7VDIP25
    DPM10T60CG3600V10A3-phase full bridge1.7VDIP25-1
    DPM10T60CG4600V10A3-phase full bridge1.7VDIP25
    DPM10T60CGS3600V10A3-phase full bridge1.7VDIP25
    DPM10T60CGS4600V10A3-phase full bridge1.7VDIP25-2
    CRM60GH15E4600V15A3-phase full bridge1.8VDIP-24B
    CRM60GH15EB600V15A3-phase full bridge1.65VDIP-24B
    CRM60GL15EA600V15A3-phase full bridge1.7VDIP-26A
    DPM15C60BG2600V15A3-phase full bridge1.8VDIP26H
    DPM15C60DG1600V15A3-phase full bridge1.8VDIP-24H
    DPM15C60DG3600V15A3-phase full bridge1.8VDIP-24H
    DPM15C60DG4600V15A3-phase full bridgeDIP-24H
    DPM15C60FG2600V15A3-phase full bridge1.6VSDIP26
    DPM15C60FG4600V15A3-phase full bridge1.6VSDIP26
    DPM15C60LG4600V15A3-phase full bridge1.6VSDIP26FP
    DPM15T60CG4600V15A3-phase full bridge1.8VDIP25
    CRM60GH20E4600V20A3-phase full bridge1.9VDIP-24B
    CRM60GH20EB600V20A3-phase full bridge1.6VDIP-24B
    DPM20C60DG1600V20A3-phase full bridge1.7VDIP-24H
    DPM20C60DG4600V20A3-phase full bridge1.7VDIP-24H
    DPM20C60DG5600V20A3-phase full bridge1.7VDIP-24H
    DPM20C60FG4600V20A3-phase full bridge1.6VSDIP26
    DPM20F60KG2600V20A3-phase full bridge1.7VDIP27
    CRM60GH30EB600V30A3-phase full bridge1.6VDIP-24B
    DPM30C60DG1600V30A3-phase full bridge1.9VDIP-24H
    DPM30C60DG5600V30A3-phase full bridge1.5VDIP-24H
    DPM30F60GG2600V30A3-phase full bridge1.7VDIP29
    DPM30F60KG2600V30A3-phase full bridge1.7VDIP27
    CRM60GH40EB600V40A3-phase full bridge1.6VDIP-24B
    DPM50F60GG2600V50A3-phase full bridge1.7VDIP29
    DPM50F60KG2600V50A3-phase full bridge1.6VDIP27

    68 part numbers share the same 600 / 3-phase full bridge rating — sorted by current; first 40 shown.

    Applications

    Fans and Hair dryer — the module's rating and package are sized for this class of load.

    Selection Notes

    • The module integrates gate drive and protection. The input side expects logic-level PWM, not a raw gate signal — do not add an external driver.
    • Fault output is open-drain on most of these modules. Fit a pull-up and latch it in the controller, otherwise the module restarts into a fault.
    • Check the dead time and minimum pulse width in the datasheet. The internal interlock is a protection layer, not a substitute for correct timing.
    • Thermal design dominates reliability. Use the module's internal thermistor or the case-to-heatsink path to size the heatsink for the actual switching loss.

    Common Questions

    What topology does the CRMT6002E1 implement?

    It is a 3-phase full bridge module rated 600 V / 3 A.

    What protection is built into the CRMT6002E1?

    The module integrates under-voltage lockout. External fault handling still has to latch the fault signal and sequence a safe restart.

    What applications is the CRMT6002E1 intended for?

    Fans and Hair dryer — a match for the module's power rating and package thermal path.

    What package does the CRMT6002E1 come in?

    SOP-23A. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.

    How do I choose between the 68 part numbers in this rating group?

    All 68 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message