The CR Micro CS5764AHMO is a 600 V 4 A intelligent power module in a ESOP12 package, wired as a half-bridge using MOSFET power stages. Protection on board covers over-temperature, over-current, fault output and short-circuit. Designed for air condition.
| Blocking Voltage (VDSS / VCES) | 600 V |
| Output Current (ID / IC) | 4 A |
| Power Stage | MOSFET |
| Circuit Configuration | half-bridge |
| Rds(on) typ. | 2.5 mΩ |
| Rds(on) max. | 3.2 mΩ |
| Built-in Protection | otp, ocp, fo, sd |
| Typical Application | air condition |
| Package | ESOP12 |
| Part Number | VDSS/VCES | ID/IC | Configuration | VCE(sat) typ | Package |
|---|---|---|---|---|---|
| CRM60TD01R1 | 600V | 1A | half-bridge | QFN 7x7 | |
| CS5762ASCO | 600V | 2A | half-bridge | WSOP13 | |
| CRM60TD03R1 | 600V | 3A | half-bridge | QFN 7x7 | |
| CS5763AHMO | 600V | 3A | half-bridge | ESOP12 | |
| CRM60TE04HA | 600V | 4A | half-bridge | SOP-11 | |
| CS5764AHMO | 600V | 4A | half-bridge | ESOP12 | |
| CS5764ASCO | 600V | 4A | half-bridge | WSOP13 | |
| CS5764SCO | 600V | 4A | half-bridge | WSOP13 | |
| CS5764SDQ | 600V | 4A | half-bridge | QFN18 | |
| CRM60TD05R1 | 600V | 5A | half-bridge | QFN 7x7 | |
| CS5765AHGO | 600V | 5A | half-bridge | 1.5V | ESOP12 |
| CS5765ASGO | 600V | 5A | half-bridge | 1.5V | WSOP13 |
| CS5765SGO | 600V | 5A | half-bridge | 1.5V | WSOP13 |
| CS5765SGQ | 600V | 5A | half-bridge | 1.5V | QFN18 |
| CRM60TE06HA | 600V | 6A | half-bridge | SOP-11 | |
| CS5766AHMO | 600V | 6A | half-bridge | ESOP12 | |
| CS5766ASCO | 600V | 6A | half-bridge | WSOP13 |
17 part numbers share the same 600 / half-bridge rating — sorted by current.
air condition — the module's rating and package are sized for this class of load.
What topology does the CS5764AHMO implement?
It is a half-bridge module rated 600 V / 4 A.
What protection is built into the CS5764AHMO?
The module integrates over-temperature, over-current, fault output, short-circuit. External fault handling still has to latch the fault signal and sequence a safe restart.
What applications is the CS5764AHMO intended for?
air condition — a match for the module's power rating and package thermal path.
What package does the CS5764AHMO come in?
ESOP12. Check the datasheet mechanical drawing for lead spacing and thermal pad dimensions before laying out the footprint.
How do I choose between the 17 part numbers in this rating group?
All 17 share the same voltage and package class. Sort by on-resistance first, then check gate charge: the lowest Rds(on) part is not automatically the best choice if the stage switches at high frequency. The table above lists them in ascending Rds(on) order.