Eaton 6125FA500mA 500 mA Fast-Blow Fuse - 6.3 x 2.5 mm, 125 Vac
Eaton 6125FA500mA 500 mA Fast-Blow Fuse - 6.3 x 2.5 mm, 125 Vac

Eaton 6125FA500mA 500 mA Fast-Blow Fuse - 6.3 x 2.5 mm, 125 Vac

Share
pEaton 6125FA500mA — 500 mA, 125 V, fast-acting fuse, 6.3 x 2.5 mm, 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc interrupting./p
    • Product Details
    • Download

    Eaton 6125FA500mA 500 mA Fast-Blow Fuse - 6.3 x 2.5 mm, 125 Vac

    Eaton 6125FA500mA 500 mA Fast-Blow Fuse - 6.3 x 2.5 mm, 125 Vac belongs to the Eaton range. It carries 500 mA, rated 125 Vac / 125 Vdc / 86 Vdc, uses a fast-acting element, measuring 3 x 2.5 mm.

    Technical Data

    ParameterRating
    Part number6125FA500mA
    Ordering codeTR2/6125FA500mA
    Packaging5,000 pcs on 12 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Typical cold resistance0.24 Ω
    Design standardEIA/IS-722
    Terminationsnickel/silver plated end terminations, solder immersion compatible
    Typical melting I2t0.06 A²s
    Agency approvalCSA component acceptance 053787 C 000, Class 1422-30; UL Recognition Guide JDYX2, File E19180
    Package6.3 x 2.5 mm (2410 imperial / 6125 metric)
    Typical voltage drop0.22 V
    Rated current500 mA
    Voltage rating125 Vac / 125 Vdc / 86 Vdc
    Interrupting rating50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc

    Design Notes

    • Interrupting capability is 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Footprint 3 x 2.5 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 125 Vac / 125 Vdc / 86 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 500 mA to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV

    Ordering Details

    Order code 6125FA500mA from Eaton, supplied in 6.3 x 2.5 mm (2410 imperial / 6125 metric). Confirm the exact suffix before release.

    Common Questions

    What are the ratings of the 6125FA500mA?

    500 mA continuous at 125 Vac / 125 Vdc / 86 Vdc, interrupting rating 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc.

    Is the 6125FA500mA fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    What size is the 6125FA500mA?

    It measures 3 x 2.5 mm. Match the holder or clip to this footprint.

    Can the 6125FA500mA be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc. Choose a part whose breaking capacity exceeds the prospective fault current.