| Parameter | Rating |
|---|---|
| Part number | ABC-1/2-R |
| End caps | nickel-plated brass |
| Rated current | 500 mA (1/2 A) |
| Design standard | UL 248-14 |
| Voltage rating, DC | 125 Vdc |
| Voltage rating | 250 Vac |
| Typical voltage drop | 0.41 V |
| Typical melting I2t | 0.039 A²s |
| Element | single element |
| Typical DC cold resistance | 0.587 Ω |
| AC interrupting rating | 35 A at 250 Vac; 10,000 A at 125 Vac; 10,000 A at 125 Vdc |
| Body | Ceramic tube, 1/4 x 1-1/4 in (6.4 x 31.7 mm) |
Common installation contexts include:
What are the ratings of the ABC-1/2-R?
500 mA continuous at 125 Vdc, interrupting rating 35 A at 250 Vac; 10,000 A at 125 Vac; 10,000 A at 125 Vdc.
Is the ABC-1/2-R fast-acting or time-delay?
It is fast-acting. Expect it to open quickly on overload.
Can the ABC-1/2-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac; 10,000 A at 125 Vac; 10,000 A at 125 Vdc. Choose a part whose breaking capacity exceeds the prospective fault current.