
| Parameter | Value |
|---|---|
| Orderable part number | AMLV06V32C010 |
| Working voltage, DC | 32 Vdc |
| Working voltage, AC | 25 Vac |
| Varistor voltage at 1 mA | 51.9 V to 70.1 V |
| Clamping voltage at 1 A | 120 V |
| Energy absorption, 10/1000 us | 0.05 J |
| Peak current, 8/20 us | 5 A |
| Typical capacitance at 1 MHz | 10 pF |
| Leakage current at working voltage | max. 20 uA |
| Package | 0603 (1608 metric) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1078 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.
The clamp column works out at 1.97 times the varistor voltage: 120 V at the rated current against 61 V at 1 mA. That ratio is what the downstream part has to survive, not the 61 V figure on the label.
Standing at 32 V the leakage is at most 20 uA, which is 0.64 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.
The 10 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the AMLV family this is item 8 of 28 in the Eaton catalogue.
The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.
Is the varistor voltage the same as the working voltage?
No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.
What does the capacitance do to my signal?
It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd