170M4952 Eaton Bussmann 1000V 200A Class aR Semiconductor Fuse
170M4952 Eaton Bussmann 1000V 200A Class aR Semiconductor Fuse

170M4952 Eaton Bussmann 1000V 200A Class aR Semiconductor Fuse

Share
Eaton Bussmann 170M4952 — 1000V 200A Class aR semiconductor fuse, 125 kAIC interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    170M4952 Eaton Bussmann 1000V 200A Class aR Semiconductor Fuse

    At a Glance
    • 1000 V (IEC) rated voltage, 200 A rated current
    • 125 kAIC interrupting rating
    • Class aR time-current characteristic
    • Centre fuse status indicator

    The Eaton Bussmann 170M4952 is a semiconductor fuse with 1000 V (IEC) rated voltage, 200 A rated current, 125 kAIC interrupting capacity, carrying a Class aR time-current characteristic. Construction is centre fuse status indicator.

    Specifications

    General specifications
    EAN5704057050197
    UPC051712679442
    Product Length/Depth160 mm
    Product Height51 mm
    Product Width70 mm
    Product Weight556 g
    Electrical data
    Amperage Rating200 A
    ClassClass aR
    Interrupt rating125 kAIC
    Voltage rating1000 V (IEC)
    Watt losses45 W
    Product specifications
    ApplicationSemiconductor, DC Common bus, DC drives, power converters/rectifiers
    Fitted with:Type K Indicator for micro
    Fuse indicatorCentre fuse status indicator
    Fuse size1
    Fuse typeFlush end BKN/Type K Indicator for Micro

    Series Selection Table

    170M4952 series selection table
    Ampere ratings, dimensions and catalog numbers across the Semiconductor Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Energy and utility distribution
    • Industrial equipment
    • Photovoltaic systems

    Selection Notes

    • Semiconductor fuses are chosen on I²t let-through against the device surge rating, not on continuous current alone.

    Common Questions

    What are the ratings of the Eaton Bussmann 170M4952?
    1000 V (IEC) / 200 A, with a 125 kAIC interrupting rating.
    How much fault current can the 170M4952 interrupt?
    125 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the 170M4952?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the 170M4952 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message