FNQ-R-7 Eaton Bussmann 600V 7A Class CC Fuse
FNQ-R-7 Eaton Bussmann 600V 7A Class CC Fuse

FNQ-R-7 Eaton Bussmann 600V 7A Class CC Fuse

Share
Eaton Bussmann FNQ-R-7 — 600V 7A Class CC fuse, 200 kAIC interrupting.
    • Product Details
    • Download

    FNQ-R-7 Eaton Bussmann 600V 7A Class CC Fuse

    At a Glance
    • 600 V rated voltage, 7 A rated current
    • 200 kAIC interrupting rating
    • Class CC time-current characteristic
    • Non-indicating

    The Eaton Bussmann FNQ-R-7 is a fuse with 600 V rated voltage, 7 A rated current, 200 kAIC interrupting capacity, carrying a Class CC time-current characteristic. Construction is a melamine tube nickel-plated brass endcap, non-indicating.

    Specifications

    General specifications
    UPC051712558259
    EAN5027590449809
    Product Length/Depth1.5 in
    Product Height0.41 in
    Product Width0.41 in
    Product Weight0.015 lb
    Product specifications
    Amperage Rating7 A
    ClassClass CC
    Interrupt rating200 kAIC
    Fuse indicatorNon-indicating
    Response time12 sec at 200%
    MaterialMelamine tube Nickel-plated brass endcap
    Packaging typeStandard
    Voltage rating600 V
    TypeCurrent-limiting high inrush time-delay fuse
    Special featuresRejection style
    ApplicationLine protection, small control transformers, industrial control, branch circuits

    Series Selection Table

    FNQ-R-7 series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment
    • Transformer protection

    Selection Notes

    • Check the voltage rating against the system voltage, and the interrupting rating against the available fault current, before specifying.

    Common Questions

    What are the ratings of the Eaton Bussmann FNQ-R-7?
    600 V / 7 A, with a 200 kAIC interrupting rating.
    How much fault current can the FNQ-R-7 interrupt?
    200 kAIC. The available fault current at the installation point must not exceed this value.
    What does Class CC mean for the FNQ-R-7?
    Class CC defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How should I select the FNQ-R-7 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products