FWH-150B Eaton Bussmann 500V 150A Class aR Semiconductor Fuse
FWH-150B Eaton Bussmann 500V 150A Class aR Semiconductor Fuse

FWH-150B Eaton Bussmann 500V 150A Class aR Semiconductor Fuse

Share
Eaton Bussmann FWH-150B — 500V 150A Class aR semiconductor fuse, 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-150B Eaton Bussmann 500V 150A Class aR Semiconductor Fuse

    At a Glance
    • 500 Vac, 500 Vdc rated voltage, 150 A rated current
    • 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting rating
    • Class aR time-current characteristic
    • Blade end x blade end terminations

    The Eaton Bussmann FWH-150B is a fuse with 500 Vac, 500 Vdc rated voltage, 150 A rated current, 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting capacity, carrying a Class aR time-current characteristic. Construction is non indicating.

    Specifications

    常用规格
    UPC051712795845
    Product Length/Depth91 mm
    Product Height30 mm
    Product Width30 mm
    Product Weight154 g
    产品规格
    Amperage Rating150 A
    Breaking capacity200 kA
    Fuse indicatorNon Indicating
    Insulated metal gripping lugs (IMGL)No
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC/DC
    Rated switching capacity200 kA
    Rated voltage AC500 V
    Rated voltage DC500 V
    Mounting dimensionM8
    Center-to-center distance of connections74.09 mm
    Current typeAC/DC
    ClassClass aR
    Clearing (I2T)4600
    Watt losses30 W
    Fuse shapeCenter bolted tags
    Pre arc (I2T)1100
    ColorNone
    Interrupt rating50 kAIC at 500 Vdc 200 kAIC at 1000 Vac
    ConnectionBlade end x blade end
    Construction sizeOther
    Mounting methodStud
    Voltage rating500 Vac, 500 Vdc
    TypeHigh speed fuse
    ApplicationSemiconductor, DC Common bus, DC drives, Power converters/rectifiers
    Fuse typeFWH-B
    Fuse system (according to IEC 60269)Other

    Series Selection Table

    FWH-150B series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-150B?
    500 Vac, 500 Vdc / 150 A, with a 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting rating.
    How much fault current can the FWH-150B interrupt?
    50 kAIC at 500 Vdc 200 kAIC at 1000 Vac. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the FWH-150B?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the FWH-150B connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-150B for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products