FWH-200B Eaton Bussmann 500V 200A Class aR Semiconductor Fuse
FWH-200B Eaton Bussmann 500V 200A Class aR Semiconductor Fuse

FWH-200B Eaton Bussmann 500V 200A Class aR Semiconductor Fuse

Share
Eaton Bussmann FWH-200B — 500V 200A Class aR semiconductor fuse, 200 kAIC at 300 Vdc 50 kAIC at 300 Vdc interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-200B Eaton Bussmann 500V 200A Class aR Semiconductor Fuse

    At a Glance
    • 500 Vac, 500 Vdc rated voltage, 200 A rated current
    • 200 kAIC at 300 Vdc 50 kAIC at 300 Vdc interrupting rating
    • Class aR time-current characteristic
    • Blade end x blade end terminations

    The Eaton Bussmann FWH-200B is a fuse with 500 Vac, 500 Vdc rated voltage, 200 A rated current, 200 kAIC at 300 Vdc 50 kAIC at 300 Vdc interrupting capacity, carrying a Class aR time-current characteristic. Construction is a ceramic, non indicating.

    Specifications

    General specifications
    UPC051712795869
    EAN5027590020916
    Product Length/Depth91 mm
    Product Height30 mm
    Product Width30 mm
    Product Weight152 g
    Global CatalogFWH-200B
    Product specifications
    Amperage Rating200 A
    Breaking capacity200 kA
    Fuse indicatorNon Indicating
    Insulated metal gripping lugs (IMGL)No
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC/DC
    Rated switching capacity200 kA
    Rated voltage AC500 V
    Rated voltage DC500 V
    Mounting dimensionM8
    Center-to-center distance of connections74.09 mm
    Current typeAC/DC
    ClassClass aR
    Clearing (I2T)8500
    Watt losses40 W
    Fuse shapeCenter bolted tags
    Pre arc (I2T)1900
    ColorWhite
    Interrupt rating200 kAIC at 300 Vdc 50 kAIC at 300 Vdc
    ConnectionBlade end x blade end
    Construction sizeOther
    MaterialCeramic
    Mounting methodStud
    Quantity1
    Voltage rating500 Vac, 500 Vdc
    TypeHigh speed fuse
    ApplicationSemiconductor, DC Common bus, DC drives, Power converters/rectifiers
    Fuse typeFWH-B
    Fuse system (according to IEC 60269)Other

    Series Selection Table

    FWH-200B series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-200B?
    500 Vac, 500 Vdc / 200 A, with a 200 kAIC at 300 Vdc 50 kAIC at 300 Vdc interrupting rating.
    How much fault current can the FWH-200B interrupt?
    200 kAIC at 300 Vdc 50 kAIC at 300 Vdc. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the FWH-200B?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the FWH-200B connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-200B for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products