FWH-225A Eaton Bussmann 500V 225A Semiconductor Fuse
FWH-225A Eaton Bussmann 500V 225A Semiconductor Fuse

FWH-225A Eaton Bussmann 500V 225A Semiconductor Fuse

Share
Eaton Bussmann FWH-225A — 500V 225A semiconductor fuse, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-225A Eaton Bussmann 500V 225A Semiconductor Fuse

    At a Glance
    • 1000 Vac, 800 Vdc rated voltage, 225A RMS rated current
    • 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating
    • Blade end x blade end terminations
    • Non Indicating

    The Eaton Bussmann FWH-225A is a fuse with 1000 Vac, 800 Vdc rated voltage, 225A RMS rated current, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting capacity. Construction is non indicating.

    Specifications

    General specifications
    UPC051712153751
    Product Length/Depth1.69 in
    Product Height1.61 in
    Product Width4.52 in
    Product Weight0.52 lb
    Electrical rating
    Amperage Rating225A RMS
    Interrupt rating200 kAIC at 1000 Vac 50 kAIC at 500 Vdc
    Voltage rating1000 Vac, 800 Vdc
    Watt losses39 W
    Physical details
    Packaging typeStandard
    General information
    ConnectionBlade end x blade end
    Fuse indicatorNon Indicating
    Mounting methodStud

    Series Selection Table

    FWH-225A series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-225A?
    1000 Vac, 800 Vdc / 225A RMS, with a 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating.
    How much fault current can the FWH-225A interrupt?
    200 kAIC at 1000 Vac 50 kAIC at 500 Vdc. The available fault current at the installation point must not exceed this value.
    How does the FWH-225A connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-225A for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd