FWH-275A Eaton Bussmann 500V 275A Semiconductor Fuse
FWH-275A Eaton Bussmann 500V 275A Semiconductor Fuse

FWH-275A Eaton Bussmann 500V 275A Semiconductor Fuse

Share
Eaton Bussmann FWH-275A — 500V 275A semiconductor fuse, 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-275A Eaton Bussmann 500V 275A Semiconductor Fuse

    At a Glance
    • 1000 Vac, 800 Vdc rated voltage, 275A RMS rated current
    • 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting rating
    • Blade end x blade end terminations
    • Non Indicating

    The Eaton Bussmann FWH-275A is a fuse with 1000 Vac, 800 Vdc rated voltage, 275A RMS rated current, 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting capacity. Construction is non indicating.

    Specifications

    General specifications
    UPC051712153775
    EAN5027590061247
    Product Length/Depth1.69 in
    Product Height1.61 in
    Product Width4.52 in
    Product Weight0.52 lb
    Electrical rating
    Amperage Rating275A RMS
    Interrupt rating50 kAIC at 500 Vdc 200 kAIC at 1000 Vac
    Voltage rating1000 Vac, 800 Vdc
    Watt losses46 W
    Physical details
    Packaging typeStandard
    General information
    ConnectionBlade end x blade end
    Fuse indicatorNon Indicating
    Mounting methodStud

    Series Selection Table

    FWH-275A series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-275A?
    1000 Vac, 800 Vdc / 275A RMS, with a 50 kAIC at 500 Vdc 200 kAIC at 1000 Vac interrupting rating.
    How much fault current can the FWH-275A interrupt?
    50 kAIC at 500 Vdc 200 kAIC at 1000 Vac. The available fault current at the installation point must not exceed this value.
    How does the FWH-275A connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-275A for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.