Eaton Bussmann FWH-50B — 500V 50A Class aR semiconductor fuse, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-50B Eaton Bussmann 500V 50A Class aR Semiconductor Fuse

    At a Glance
    • 500 Vac, 500 Vdc rated voltage, 50 A rated current
    • 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating
    • Class aR time-current characteristic
    • Blade end x blade end terminations

    The Eaton Bussmann FWH-50B is a fuse with 500 Vac, 500 Vdc rated voltage, 50 A rated current, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting capacity, carrying a Class aR time-current characteristic. Construction is non indicating.

    Specifications

    General specifications
    Model Code50A 500V AC TAG FUSE
    UPC051712795777
    EAN5027590499682
    Product Length/Depth108 mm
    Product Height28 mm
    Product Width90 mm
    Product Weight63 g
    Global CatalogFWH-50B
    Product specifications
    Amperage Rating50 A
    Breaking capacity200 kA
    Fuse indicatorNon Indicating
    Insulated metal gripping lugs (IMGL)No
    Utilization categoryaR (accompanied semiconductor protection)
    Voltage typeAC/DC
    Rated switching capacity200 kA
    Rated voltage AC500 V
    Rated voltage DC500 V
    Mounting dimensionM8
    Center-to-center distance of connections60.75 mm
    Current typeAC/DC
    ClassClass aR
    Clearing (I2T)670
    Watt losses7.5 W
    Fuse shapeCylindrical, center bolted tags
    Pre arc (I2T)135
    ColorNone
    Interrupt rating200 kAIC at 1000 Vac 50 kAIC at 500 Vdc
    ConnectionBlade end x blade end
    Construction sizeOther
    Mounting methodStud
    Voltage rating500 Vac, 500 Vdc
    TypeHigh speed fuse
    ApplicationSemiconductor, DC Common bus, DC drives, Power converters/rectifiers
    Fuse typeFWH-B
    Fuse system (according to IEC 60269)Other

    Series Selection Table

    FWH-50B series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-50B?
    500 Vac, 500 Vdc / 50 A, with a 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating.
    How much fault current can the FWH-50B interrupt?
    200 kAIC at 1000 Vac 50 kAIC at 500 Vdc. The available fault current at the installation point must not exceed this value.
    What does Class aR mean for the FWH-50B?
    Class aR defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the FWH-50B connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-50B for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.