FWH-90BC Eaton Bussmann 500V 90A Semiconductor Fuse
FWH-90BC Eaton Bussmann 500V 90A Semiconductor Fuse

FWH-90BC Eaton Bussmann 500V 90A Semiconductor Fuse

Share
Eaton Bussmann FWH-90BC — 500V 90A semiconductor fuse, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting. Protects semiconductors in drives, rectifiers and inverters.
    • Product Details
    • Download

    FWH-90BC Eaton Bussmann 500V 90A Semiconductor Fuse

    At a Glance
    • 500 V rated voltage, 90 A rated current
    • 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating
    • Blade end x blade end terminations
    • None

    The Eaton Bussmann FWH-90BC is a fuse with 500 V rated voltage, 90 A rated current, 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting capacity. Construction is none.

    Specifications

    General specifications
    EAN5027590581738
    Product Length/Depth91 mm
    Product Height24 mm
    Product Width24 mm
    Product Weight95 g
    Global CatalogFWH-90BC
    Product specifications
    Amperage Rating90 A
    Breaking capacity200 kA
    Fuse indicatorNone
    Insulated metal gripping lugs (IMGL)No
    Utilization categoryOther
    Voltage typeAC/DC
    Rated switching capacity200 A
    Clearing (I2T)1600
    Watt losses15 W
    Fuse shapeCenter bolted tags
    Pre arc (I2T)360
    Interrupt rating200 kAIC at 1000 Vac 50 kAIC at 500 Vdc
    ConnectionBlade end x blade end
    Construction sizeOther
    Mounting methodStud
    Voltage rating500 V
    TypeHigh speed fuse
    Applicationprotection of DC common bus, DC drives, power converters/rectifiers and reduced voltage starters

    Series Selection Table

    FWH-90BC series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Blade end x blade end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann FWH-90BC?
    500 V / 90 A, with a 200 kAIC at 1000 Vac 50 kAIC at 500 Vdc interrupting rating.
    How much fault current can the FWH-90BC interrupt?
    200 kAIC at 1000 Vac 50 kAIC at 500 Vdc. The available fault current at the installation point must not exceed this value.
    How does the FWH-90BC connect?
    Blade end x blade end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the FWH-90BC for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message