LP-CC-1-1/2 Eaton Bussmann 1.5A Class CC Fuse
LP-CC-1-1/2 Eaton Bussmann 1.5A Class CC Fuse

LP-CC-1-1/2 Eaton Bussmann 1.5A Class CC Fuse

Share
Eaton Bussmann LP-CC-1-1/2 — 1.5A Class CC fuse, 200 kAIC at 600 Vac 20 kAIC at 300 Vdc interrupting.
    • Product Details
    • Download

    LP-CC-1-1/2 Eaton Bussmann 1.5A Class CC Fuse

    At a Glance
    • 600 Vac, 300 Vdc rated voltage, 1.5 A rated current
    • 200 kAIC at 600 Vac 20 kAIC at 300 Vdc interrupting rating
    • Class CC time-current characteristic
    • Ferrule end x ferrule end terminations

    The Eaton Bussmann LP-CC-1-1/2 is a fuse with 600 Vac, 300 Vdc rated voltage, 1.5 A rated current, 200 kAIC at 600 Vac 20 kAIC at 300 Vdc interrupting capacity, carrying a Class CC time-current characteristic. Construction is a melamine tube, non-indicating.

    Specifications

    General specifications
    UPC051712180474
    Product Length/Depth1.5 in
    Product Height0.41 in
    Product Width0.41 in
    Product Weight0.15 lb
    Product specifications
    Amperage Rating1.5 A
    Number of elementsDual
    ClassClass CC
    Interrupt rating200 kAIC at 600 Vac 20 kAIC at 300 Vdc
    Fuse indicatorNon-indicating
    ConnectionFerrule end x ferrule end
    Response time12 sec at 200%
    MaterialMelamine tube
    Packaging typeStandard
    Quantity10
    Voltage rating600 Vac, 300 Vdc
    TypeCurrent-limiting time-delay fuse
    Special featuresRejection style
    ApplicationSpecialized circuits and industrial control

    Series Selection Table

    LP-CC-1-1/2 series selection table
    Ampere ratings, dimensions and catalog numbers across the Fuse family, reproduced from the Eaton Bussmann datasheet.

    Applications

    • Industrial equipment

    Selection Notes

    • Termination: Ferrule end x ferrule end. Confirm the mating clip or busbar before ordering; ferrule and blade ends are not interchangeable.

    Common Questions

    What are the ratings of the Eaton Bussmann LP-CC-1-1/2?
    600 Vac, 300 Vdc / 1.5 A, with a 200 kAIC at 600 Vac 20 kAIC at 300 Vdc interrupting rating.
    How much fault current can the LP-CC-1-1/2 interrupt?
    200 kAIC at 600 Vac 20 kAIC at 300 Vdc. The available fault current at the installation point must not exceed this value.
    What does Class CC mean for the LP-CC-1-1/2?
    Class CC defines the fuse's time-current characteristic. E-rated fuses carry a defined melting curve so they coordinate predictably with upstream and downstream devices; mixing E and non-E ratings in one feeder defeats that coordination.
    How does the LP-CC-1-1/2 connect?
    Ferrule end x ferrule end. Confirm the mating clip, holder or busbar before ordering — ferrule and blade ends are not interchangeable.
    How should I select the LP-CC-1-1/2 for a circuit?
    Match the voltage rating to the system voltage, keep the continuous current above the load current, and check that the interrupting rating exceeds the available fault current. In medium voltage work, select on the transformer or feeder fault level rather than the load current alone.