The CC06FA1.5A is the 1.5 A part of the CC06FA family - an 0603 (1608 metric) chip fuse rated 63 Vdc with 50 A interrupting capacity. Supplied as CC06FA1-5A-TR - 5,000 pieces in paper tape on a 178 mm (7 inch) reel.
| Parameter | Value |
|---|---|
| Manufacturer / Series | Eaton / CC06FA Series |
| Orderable part number | CC06FA1.5A (RoHS suffix -R form CC06FAxxx-R) |
| Ordering code | CC06FA1-5A-TR |
| Packaging | 5,000 pcs in paper tape, 178 mm (7 in) reel |
| Current rating | 1.5 A |
| Voltage rating | 63 Vdc |
| Interrupting rating | 50 A |
| Typical DC cold resistance | 0.086 Ohm |
| Typical pre-arcing I2t | 0.0319 A2s |
| Typical voltage drop | 0.138 V |
| Part marking | K |
| Package | 0603 (1608 metric) surface mount chip, ceramic and glass construction |
| AEC-Q200 | qualified |
| Lead free | yes |
| Agency / environmental | UL Recognized file E19180; AEC-Q200 qualified |
| % of rating / condition | Opening time |
|---|---|
| 100 % | 4 hours minimum |
| 200 % | 60 seconds maximum |
On the DC side 1.5 A is sized from the continuous battery or bus current plus the ambient derating, not from a branch-circuit rule of thumb. Check the prospective short-circuit current against the breaking capacity in the table before fixing the rating.
CC06FA1.5A (RoHS suffix -R form CC06FAxxx-R); the packaging prefix, where the series uses one, goes in front of the part number rather than after it.Can CC06FA1.5A replace the next rating up in an existing design?
No. Dropping from a higher rating changes both the continuous headroom and the I2t, so a fuse that used to ride through inrush may now open on it. Match current, voltage, I2t and body before substituting.
What fault current can CC06FA1.5A clear?
50 A at rated voltage. That figure assumes a normal branch-circuit source impedance; a stiff transformer feeding the same circuit can exceed it, and then the fuse is no longer the protective device by design.
Will CC06FA1.5A carry 1.5 A continuously without opening?
Yes. The published table shows no opening at 100 % of rating, so 1.5 A is inside the continuous rating at 25 C. Ambient temperature inside the enclosure, not the nominal current, is what usually forces the next size up.
Design note: resistance, I2t and voltage-drop values are typical unless identified as ratings. Verify the current data sheet and curves before release.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd