    The CC06FA750mA is the 750 mA part of the CC06FA family - an 0603 (1608 metric) chip fuse rated 63 Vdc with 50 A interrupting capacity. Supplied as CC06FA750mA-TR - 5,000 pieces in paper tape on a 178 mm (7 inch) reel.

    Core Specifications

    ParameterValue
    Manufacturer / SeriesEaton / CC06FA Series
    Orderable part numberCC06FA750mA (RoHS suffix -R form CC06FAxxx-R)
    Ordering codeCC06FA750mA-TR
    Packaging5,000 pcs in paper tape, 178 mm (7 in) reel
    Current rating0.75 A
    Voltage rating63 Vdc
    Interrupting rating50 A
    Typical DC cold resistance0.510 Ohm
    Typical pre-arcing I2t0.003 A2s
    Typical voltage drop0.50 V
    Part markingG
    Package0603 (1608 metric) surface mount chip, ceramic and glass construction
    AEC-Q200qualified
    Lead freeNO - values below 1 A are not lead free
    Agency / environmentalUL Recognized file E19180; AEC-Q200 qualified

    Electrical Characteristics

    % of rating / conditionOpening time
    100 %4 hours minimum
    200 %60 seconds maximum

    At 750 mA

    • Heat at this rating. 500 mV drop across 750 mA works out to 0.375 W in the element; the cold resistance of 0.51 Ohm would suggest only 0.2869 W, so the rest is the element's own temperature rise. Layout the copper for the higher figure.
    • Interruption. 50 A at the rated voltage is what this part is tested to clear. Above that the enclosure rather than the element decides what happens, so the prospective fault current is part of the application check, not only the load.
    • Position in the range. Sits between CC06FA500mA and CC06FA1A in the range. Stepping down to CC06FA500mA trips sooner on light overload but leaves less continuous headroom; CC06FA1A trades the other way.

    Where 750 mA Fits

    On the DC side 750 mA is sized from the continuous battery or bus current plus the ambient derating, not from a branch-circuit rule of thumb. Check the prospective short-circuit current against the breaking capacity in the table before fixing the rating.

    Rating-Specific Notes

    • Values below 1 A are not lead free; the AEC-Q200 qualification covers the range but the RoHS declaration does not.

    For Procurement

    • Order CC06FA750mA. The orderable reference on this page reads CC06FA750mA (RoHS suffix -R form CC06FAxxx-R); the packaging prefix, where the series uses one, goes in front of the part number rather than after it.
    • Agency / compliance for this rating: UL Recognized file E19180; AEC-Q200 qualified.
    • 750 mA is not interchangeable with the neighbouring rating beyond its name: the current, the terminal arrangement and the body dimensions all have to match.

    Frequently Asked Questions

    Will CC06FA750mA carry 750 mA continuously without opening?
    Yes. The published table shows no opening at 100 % of rating, so 750 mA is inside the continuous rating at 25 C. Ambient temperature inside the enclosure, not the nominal current, is what usually forces the next size up.

    Can CC06FA750mA replace the next rating up in an existing design?
    No. Dropping from a higher rating changes both the continuous headroom and the I2t, so a fuse that used to ride through inrush may now open on it. Match current, voltage, I2t and body before substituting.

    What fault current can CC06FA750mA clear?
    50 A at rated voltage. That figure assumes a normal branch-circuit source impedance; a stiff transformer feeding the same circuit can exceed it, and then the fuse is no longer the protective device by design.

    Design note: resistance, I2t and voltage-drop values are typical unless identified as ratings. Verify the current data sheet and curves before release.

    Mechanical Dimensions