Eaton CL0608-2-100TR-R: 2-phase multi-phase power inductor, 100 nH per phase, 0.89 mOhm DCR, 15 A rated per phase.
    • Product Details
    • Download

    Eaton CL0608-2-100TR-R 2-Phase Multi-Phase Power Inductor, 100 nH per phase

    CL0608-2-100TR-R at a glance: 2-phase multi-phase power inductor, 0.89 mOhm DCR, 15 A rated current per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL0608-2-100TR-R
    Rated inductance per phase100 nH ±20%
    Number of phases2
    Open circuit inductance (OCL)380 nH
    Full load inductance (FLL)300 nH minimum
    DC resistance (DCR)0.89 mOhm
    Rated current per phase15 A
    Peak current per phase38 A
    PackageCL0608 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The 15 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.

    Where This Series Fits

    CL0608 是 CL 系列里最小的多相功率电感,2 相版本,100 nH 级电感。

    • Typical use: 多相 VRM、GPU/ASIC 供电、小型服务器.
    • 多相电感的相数决定铜损和纹波抑制能力。相数越多,单相电流越小,DCR 损耗随之下降。
    • Data sheet 4303; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl0608-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message