| Parameter | Value |
|---|---|
| Orderable part number | CL0608-2-100TR-R |
| Rated inductance per phase | 100 nH ±20% |
| Number of phases | 2 |
| Open circuit inductance (OCL) | 380 nH |
| Full load inductance (FLL) | 300 nH minimum |
| DC resistance (DCR) | 0.89 mOhm |
| Rated current per phase | 15 A |
| Peak current per phase | 38 A |
| Package | CL0608 footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
The 15 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.
Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.
CL0608 是 CL 系列里最小的多相功率电感,2 相版本,100 nH 级电感。
Saturation is a hard limit, not a derating curve. In a multi-phase converter the phases share the load, so a single phase that saturates first takes the whole transient on its own shoulders. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.
What does the phase count mean?
The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.
What is Isat?
The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.
How do the phases connect?
The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd