Eaton CL0904-2-50TR-R Multi-Phase Power Inductor, 2 phases, 50 nH per phase
Eaton CL0904-2-50TR-R Multi-Phase Power Inductor, 2 phases, 50 nH per phase

Eaton CL0904-2-50TR-R Multi-Phase Power Inductor, 2 phases, 50 nH per phase

Share
Eaton CL0904-2-50TR-R: 2-phase multi-phase power inductor, 50 nH per phase, 0.35 mOhm DCR, 35 A rated per phase.
    • Product Details
    • Download

    Eaton CL0904-2-50TR-R Multi-Phase Power Inductor, 2 phases, 50 nH per phase

    CL0904-2-50TR-R: 2-phase power inductor, OCL 320 nH / 320 nH (per pin pair), DCR 0.35 mOhm, 35 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL0904-2-50TR-R
    Number of phases2
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)320 nH / 320 nH (per pin pair)
    DC resistance (DCR)0.35 mOhm
    Rated current per phase35 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc245 nH
    PackageCL0904 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The 35 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.35 mOhm at 20 °C is the number that sets efficiency. At 35 A per phase the winding loss is 0.4 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Series Positioning

    CL0904 是 50 nH 的多相功率电感,2 相与 3 相两个版本。

    • Typical use: CPU/GPU 多相 VRM、高频大电流供电.
    • 额定电感按 Volterra 测试法确定,实际设计要用回路仿真核对相位与纹波。
    • Data sheet Volterra; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 320 nH / 320 nH (per pin pair) measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl0904-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.