    CL0904-3-50TR-R: 3-phase power inductor, OCL 400 nH / 380 nH (per pin pair), DCR 0.35 mOhm, 35 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL0904-3-50TR-R
    Number of phases3
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)400 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.35 mOhm
    Rated current per phase35 A
    Peak current per phase50 A
    Magnetizing inductance @ 5 Adc250 nH
    PackageCL0904 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 3 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    DCR 0.35 mOhm at 20 °C is the number that sets efficiency. At 35 A per phase the winding loss is 0.4 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Where This Series Fits

    CL0904 是 50 nH 的多相功率电感,2 相与 3 相两个版本。

    • Typical use: CPU/GPU 多相 VRM、高频大电流供电.
    • 额定电感按 Volterra 测试法确定,实际设计要用回路仿真核对相位与纹波。
    • Data sheet Volterra; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 35 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 3 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 3-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.