| Parameter | Value |
|---|---|
| Orderable part number | CL1108-2-50TR-R |
| Number of phases | 2 |
| Rated inductance per phase | 50 nH ±20% |
| Open circuit inductance (OCL) | 380 nH / 380 nH (per pin pair) |
| DC resistance (DCR) | 0.28 mOhm |
| Rated current per phase | 50 A |
| Peak current per phase | 80 A |
| Magnetizing inductance @ 5 Adc | 300 nH |
| Package | CL1108 footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 2 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.
DCR 0.28 mOhm at 20 °C is the number that sets efficiency. At 50 A per phase the winding loss is 0.7 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.
CL1108 是标准型 50 nH 多相功率电感,2 到 5 相可选。
Isat marks where the part leaves its inductive region. At 50 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.
What does the phase count mean?
The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.
What does the phase count mean?
The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd