Eaton CL1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated
Eaton CL1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

Eaton CL1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

Share
Eaton CL1108-2-50TR-R: 2-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CL1108-2-50TR-R 2-Phase VRM Inductor 50 nH per phase, 50 A Rated

    CL1108-2-50TR-R at a glance: 2-phase multi-phase power inductor, 0.28 mOhm DCR, 50 A rated current per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCL1108-2-50TR-R
    Number of phases2
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)380 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCL1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 2 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    DCR 0.28 mOhm at 20 °C is the number that sets efficiency. At 50 A per phase the winding loss is 0.7 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Where This Series Fits

    CL1108 是标准型 50 nH 多相功率电感,2 到 5 相可选。

    • Typical use: 多相 VRM、服务器 CPU 供电、以太网 PHY 供电.
    • 相位引脚在 (3-4)(5-6)… 与 (1-2)(7-8)… 两组上,PCB 布线必须让每相电流回路闭合。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 50 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.