Eaton CL1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase
Eaton CL1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Eaton CL1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Share
Eaton CL1108-4-50TR-R: 4-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CL1108-4-50TR-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

    CL1108-4-50TR-R: 4-phase power inductor, OCL 400 nH / 380 nH (per pin pair), DCR 0.28 mOhm, 50 A per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCL1108-4-50TR-R
    Rated inductance per phase50 nH ±20%
    Number of phases4
    Open circuit inductance (OCL)400 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCL1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    With 4 phases of 50 nH each, the ripple on a given rail is the sum of the individual phase currents. Adding phases does not just divide the current - it also shapes the ripple, which is why the phase count is part of the VRM design rather than a purchasing decision.

    DCR 0.28 mOhm is why the 4-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Where This Series Fits

    CL1108 是标准型 50 nH 多相功率电感,2 到 5 相可选。

    • Typical use: 多相 VRM、服务器 CPU 供电、以太网 PHY 供电.
    • 相位引脚在 (3-4)(5-6)… 与 (1-2)(7-8)… 两组上,PCB 布线必须让每相电流回路闭合。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 50 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Can I use fewer phases than the part number?
    No. The part number fixes the phase count and the pinout that goes with it.

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.