Eaton CL1108-5-50TR-R - 5-Phase 50 nH per phase Power Inductor, 0.28 mOhm DCR
Eaton CL1108-5-50TR-R - 5-Phase 50 nH per phase Power Inductor, 0.28 mOhm DCR

Eaton CL1108-5-50TR-R - 5-Phase 50 nH per phase Power Inductor, 0.28 mOhm DCR

Share
Eaton CL1108-5-50TR-R: 5-phase multi-phase power inductor, 50 nH per phase, 0.28 mOhm DCR, 50 A rated per phase.
    • Product Details
    • Download

    Eaton CL1108-5-50TR-R - 5-Phase 50 nH per phase Power Inductor, 0.28 mOhm DCR

    CL1108-5-50TR-R at a glance: 5-phase multi-phase power inductor, 0.28 mOhm DCR, 50 A rated current per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL1108-5-50TR-R
    Number of phases5
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)400 nH / 380 nH (per pin pair)
    DC resistance (DCR)0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    Magnetizing inductance @ 5 Adc300 nH
    PackageCL1108 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    With 5 phases of 50 nH each, the ripple on a given rail is the sum of the individual phase currents. Adding phases does not just divide the current - it also shapes the ripple, which is why the phase count is part of the VRM design rather than a purchasing decision.

    Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.

    Series Positioning

    CL1108 是标准型 50 nH 多相功率电感,2 到 5 相可选。

    • Typical use: 多相 VRM、服务器 CPU 供电、以太网 PHY 供电.
    • 相位引脚在 (3-4)(5-6)… 与 (1-2)(7-8)… 两组上,PCB 布线必须让每相电流回路闭合。
    • Data sheet 4306; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 400 nH / 380 nH (per pin pair) measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 5 phases is a high-current configuration. Per-phase current is low enough that copper loss stays small even with 50 A in each winding, which is the whole point of going to this many phases.

    Frequently Asked Questions

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Can I use fewer phases than the part number?
    No. The part number fixes the phase count and the pinout that goes with it.

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1108-cla1108-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd