Eaton CL1110-2-100TR-R - 2-Phase 100 nH per phase Power Inductor, 0.63 mOhm DCR
Eaton CL1110-2-100TR-R - 2-Phase 100 nH per phase Power Inductor, 0.63 mOhm DCR

Eaton CL1110-2-100TR-R - 2-Phase 100 nH per phase Power Inductor, 0.63 mOhm DCR

Share
Eaton CL1110-2-100TR-R: 2-phase multi-phase power inductor, 100 nH per phase, 0.63 mOhm DCR, 15 A rated per phase.
    • Product Details
    • Download

    Eaton CL1110-2-100TR-R - 2-Phase 100 nH per phase Power Inductor, 0.63 mOhm DCR

    CL1110-2-100TR-R at a glance: 2-phase multi-phase power inductor, 0.63 mOhm DCR, 15 A rated current per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL1110-2-100TR-R
    Number of phases2
    Rated inductance per phase100 nH ±20%
    Open circuit inductance (OCL)450 nH / 450 nH (per pin pair)
    Full load inductance (FLL)340 nH minimum
    DC resistance (DCR)0.63 mOhm
    Rated current per phase15 A
    PackageCL1110 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The 15 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.63 mOhm is why the 2-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Where This Series Fits

    CL1110 是 100 nH 的多相电感,2 / 4 / 6 相,OCL 到 470 nH。

    • Typical use: 多相 VRM、大电流 POL.
    • OCL 是在 0 Adc 下测的,带载后实际电感会掉到 FLL 的水平,纹波计算要用 FLL。
    • Data sheet 4310; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 450 nH / 450 nH (per pin pair) measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1110-multi-phase-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd