| Parameter | Value |
|---|---|
| Orderable part number | CL1110R1-4-R050-R |
| Rated inductance per phase | 50 nH ±20% |
| Number of phases | 4 |
| Open circuit inductance (OCL) | 250 nH typical / 220 nH minimum |
| Full load inductance (FLL) | 200 nH minimum |
| DC resistance (DCR) | 0.3 mOhm |
| Rated current per phase | 20 A |
| Peak current per phase | 70 A |
| Package | CL1110R footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
The 20 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.
Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.
CL1110R 是 R1 版本的 50 nH 多相电感,给出 Isat1/Isat2/Isat3 三档饱和电流。
Isat marks where the part leaves its inductive region. At 20 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
What is Isat?
The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.
How do the phases connect?
The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd