Eaton CL1110R1-4-R050-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase
Eaton CL1110R1-4-R050-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Eaton CL1110R1-4-R050-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

Share
Eaton CL1110R1-4-R050-R: 4-phase multi-phase power inductor, 50 nH per phase, 0.3 mOhm DCR, 20 A rated per phase.
    • Product Details
    • Download

    Eaton CL1110R1-4-R050-R Multi-Phase Power Inductor, 4 phases, 50 nH per phase

    CL1110R1-4-R050-R: 4-phase power inductor, OCL 250 nH typical / 220 nH minimum, DCR 0.3 mOhm, 20 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL1110R1-4-R050-R
    Rated inductance per phase50 nH ±20%
    Number of phases4
    Open circuit inductance (OCL)250 nH typical / 220 nH minimum
    Full load inductance (FLL)200 nH minimum
    DC resistance (DCR)0.3 mOhm
    Rated current per phase20 A
    Peak current per phase70 A
    PackageCL1110R footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The 20 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.

    Where This Series Fits

    CL1110R 是 R1 版本的 50 nH 多相电感,给出 Isat1/Isat2/Isat3 三档饱和电流。

    • Typical use: 多相 VRM、服务器供电.
    • 三个 Isat 分别对应不同测试条件:Isat1 是 FLL 测量点,Isat2 是 OCL@Isat 曲线,Isat3 是 SCL 下降 20% 的点。
    • Data sheet 4313; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 20 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1110r-multi-phase-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd