    CL1110R1-6-R050-R at a glance: 6-phase multi-phase power inductor, 0.3 mOhm DCR, 20 A rated current per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCL1110R1-6-R050-R
    Rated inductance per phase50 nH ±20%
    Number of phases6
    Open circuit inductance (OCL)250 nH typical / 220 nH minimum
    Full load inductance (FLL)200 nH minimum
    DC resistance (DCR)0.3 mOhm
    Rated current per phase20 A
    Peak current per phase70 A
    PackageCL1110R footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The 20 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.

    Series Positioning

    CL1110R 是 R1 版本的 50 nH 多相电感,给出 Isat1/Isat2/Isat3 三档饱和电流。

    • Typical use: 多相 VRM、服务器供电.
    • 三个 Isat 分别对应不同测试条件:Isat1 是 FLL 测量点,Isat2 是 OCL@Isat 曲线,Isat3 是 SCL 下降 20% 的点。
    • Data sheet 4313; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 250 nH typical / 220 nH minimum measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 6 phases is a high-current configuration. Per-phase current is low enough that copper loss stays small even with 20 A in each winding, which is the whole point of going to this many phases.

    Frequently Asked Questions

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.