Eaton CL1208-2-100TR-R: 2-phase multi-phase power inductor, 100 nH per phase, 0.45 mOhm DCR, 15 A rated per phase.
    • Product Details
    • Download

    Eaton CL1208-2-100TR-R 2-Phase VRM Inductor 100 nH per phase, 15 A Rated

    CL1208-2-100TR-R: 2-phase power inductor, OCL 400 nH typical / 360 nH minimum, DCR 0.45 mOhm, 15 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL1208-2-100TR-R
    Number of phases2
    Rated inductance per phase100 nH ±20%
    Open circuit inductance (OCL)400 nH typical / 360 nH minimum
    Full load inductance (FLL)320 nH minimum
    DC resistance (DCR)0.45 mOhm
    Rated current per phase15 A
    Peak current per phase56 A
    PackageCL1208 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 2 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    DCR 0.45 mOhm at 20 °C is the number that sets efficiency. At 15 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Where This Series Fits

    CL1208 是 100 nH 多相电感,2 / 3 / 4 / 6 相,DCR 低到 0.45 mOhm。

    • Typical use: 高电流多相 VRM、GPU 供电.
    • 低 DCR 是这个系列的核心卖点:损耗低,效率高。代价是对电流纹波和相间平衡设计要求更高。
    • Data sheet 4314; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 15 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. Two phases is the entry point of the family: one extra winding against the single-phase alternative, halving the current in each winding at the cost of a slightly larger footprint and one more layer of control.

    Frequently Asked Questions

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.