| Parameter | Value |
|---|---|
| Orderable part number | CL1208-4-100TR-R |
| Rated inductance per phase | 100 nH ±20% |
| Number of phases | 4 |
| Open circuit inductance (OCL) | 400 nH typical / 360 nH minimum |
| Full load inductance (FLL) | 320 nH minimum |
| DC resistance (DCR) | 0.45 mOhm |
| Rated current per phase | 15 A |
| Peak current per phase | 56 A |
| Package | CL1208 footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
The 15 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.
DCR 0.45 mOhm at 20 °C is the number that sets efficiency. At 15 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.
CL1208 是 100 nH 多相电感,2 / 3 / 4 / 6 相,DCR 低到 0.45 mOhm。
OCL is the open-circuit inductance: 400 nH typical / 360 nH minimum measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
What is Isat?
The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd