Eaton CL1208-4-100TR-R Multi-Phase Power Inductor, 4 phases, 100 nH per phase
Eaton CL1208-4-100TR-R Multi-Phase Power Inductor, 4 phases, 100 nH per phase

Eaton CL1208-4-100TR-R Multi-Phase Power Inductor, 4 phases, 100 nH per phase

Share
Eaton CL1208-4-100TR-R: 4-phase multi-phase power inductor, 100 nH per phase, 0.45 mOhm DCR, 15 A rated per phase.
    • Product Details
    • Download

    Eaton CL1208-4-100TR-R Multi-Phase Power Inductor, 4 phases, 100 nH per phase

    CL1208-4-100TR-R: 4-phase power inductor, OCL 400 nH typical / 360 nH minimum, DCR 0.45 mOhm, 15 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCL1208-4-100TR-R
    Rated inductance per phase100 nH ±20%
    Number of phases4
    Open circuit inductance (OCL)400 nH typical / 360 nH minimum
    Full load inductance (FLL)320 nH minimum
    DC resistance (DCR)0.45 mOhm
    Rated current per phase15 A
    Peak current per phase56 A
    PackageCL1208 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The 15 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.45 mOhm at 20 °C is the number that sets efficiency. At 15 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Series Positioning

    CL1208 是 100 nH 多相电感,2 / 3 / 4 / 6 相,DCR 低到 0.45 mOhm。

    • Typical use: 高电流多相 VRM、GPU 供电.
    • 低 DCR 是这个系列的核心卖点:损耗低,效率高。代价是对电流纹波和相间平衡设计要求更高。
    • Data sheet 4314; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 400 nH typical / 360 nH minimum measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Which inductance should I use?
    The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1208-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message